Inspections for the day of: Tuesday, April 19, 2016.
Number of inspections: 21
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-00542 ELE-Aging Inspection4/19/20164/19/20164/26/2016 3:22:11 PM PASS
Waiting on contractor
ELE13-00835 ELE-Aging Inspection4/19/20164/19/20164/20/2016 3:03:20 PM PASS
Waiting on contractor
ELE13-02280 ELE-Aging Inspection4/19/20164/19/20164/20/2016 3:01:27 PM PASS
Waiting on contractor
ELE16-01236 Final4/18/20164/19/20164/19/2016 3:20:24 PMPPASS
Phone #: ###-#### Inspection requested via web by cory carman
Final ok
ELE13-01886 ELE-Aging Inspection4/19/20164/19/20164/19/2016 3:10:57 PM PASS
Drove by and inspected
ELE13-01886 Final4/19/20164/19/20164/19/2016 2:52:08 PMPPASS
Listing and disconnecting means confirmed. Final ok
ELE16-01193 Electrical Rough-In4/18/20164/19/20164/19/2016 2:43:53 PMPNR
Wes Phone #: ###-####
Still need strapping, GFCI devices need to be readily accessible. Will recall
ELE16-01236 Electrical Rough-In4/19/20164/19/20164/19/2016 1:58:35 PMPPASS
Phone #: ###-#### Inspection requested via web by cory carman
All non-metallic shell, perimeter bond, low voltage LED fixture, bonding of equipment, underground, required receptacle outlet rough in ok cover
ELE16-01154 Rough-In Permanent Service4/19/20164/19/20164/19/2016 1:55:16 PMPPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn
Rough in ok cover p/s u/g n ok
ELE16-00981 Temporary Service4/19/20164/19/20164/19/2016 1:13:36 PMPPASS
250 GFCI corrected. Final ok
ELE16-01251 Permanent Service4/19/20164/19/20164/19/2016 1:10:20 PMPCANC
This is for underground conduits ......pls. call Daven Story 30 mins. before arrival. Thanks Phone #: ###-#### Inspection requested via web by Brian Caruso
Needed rough in for underground.
ELE16-01251 Electrical Rough-In4/19/20164/19/20164/19/2016 1:09:41 PMPPASS
This is for underground conduits ......pls. call Daven Story 30 mins. before arrival. Thanks Phone #: ###-#### Inspection requested via web by Brian Caruso
Underground rough in ok cover
ELE16-01190 Permanent Service4/14/20164/19/20164/19/2016 12:27:29 PMPPASS
Jeremy Kuntz is contact, ###-####... Phone #: ###-#### Inspection requested via web by Debby Pierce
Replace damaged service mast. Recently changed service. p/s o/h rec ok
ELE16-01190 Final4/19/20164/19/20164/19/2016 12:17:31 PMPPASS
Jeremy Kuntz is contact, ###-####... Phone #: ###-#### Inspection requested via web by Debby Pierce
Permit to repair damaged mast. Final ok
ELE16-01246 Conference4/19/20164/19/20164/19/2016 12:00:56 PMPDONE
Phone #: ###-#### Inspection requested via web by shane miller
Discussed mounting temp service to side of house and running sch.40 pvc on surface of houseto sub-feed existing panel. Shall establish ground at temp service, seperate ground and neutrals at existing location. Remove bushes for work space for temp and new service when set.
ELE16-00932 Electrical Rough-In4/18/20164/19/20164/19/2016 11:36:48 AMAPASS
We are requesting a ceiling rough-in inspection for tomorrow 4/19/16 in the morning. Our contact is Rich @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
East and west vestibule grid rough in ok cover
ELE16-01240 Rough-In Permanent Service4/18/20164/19/20164/19/2016 10:27:13 AMAPASS
Phone #: ###-#### Inspection requested via web by Richard Gratiot
Rough in ok cover p/s u/g n ok
ELE16-01195 Permanent Service4/18/20164/19/20164/19/2016 9:58:21 AMAPASS
Lock Box Code is 3701. Phone #: ###-#### Inspection requested via web by Sean DeLacy p/s u/g rec ok
ELE16-01195 Final4/19/20164/19/20164/19/2016 9:57:28 AMPFAIL
Lock Box Code is 3701. Phone #: ###-#### Inspection requested via web by Sean DeLacy
314.23- AC disconnect next to meter shall be secured to structure and bushing shall be installed as per 300.4(B)(1).
422.30- Disconnecting means shall be provided for water heater.
406.6- Dryer cover plate shall totally cover box opening.
*Check old water heater location in garage to make sure disconnected and blank.
ELE16-01229 Rough-In Permanent Service4/18/20164/19/20164/19/2016 9:05:23 AMAPASS
Phone #: ###-#### Inspection requested via web by Darryn Coburn
Rough in ok cover p/s u/g n ok
ELE16-01156 Rough-In Permanent Service4/18/20164/19/20164/19/2016 8:40:45 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn
Rough in ok cover p/s u/g n ok