PLM16-03554
| PLM-Aging Inspection | 4/19/2017 | 4/19/2017 | 4/25/2017 12:01:49 PM | | PEND |
|
|
Gave tenant a business card and the owner will call.
|
PLM16-03527
| PLM-Aging Inspection | 4/19/2017 | 4/19/2017 | 4/24/2017 10:53:23 AM | | PEND |
|
|
Talked to contractors office. Following up to comfirm
|
PLM16-02305
| PLM-Aging Inspection | 4/19/2017 | 4/19/2017 | 4/20/2017 1:22:18 PM | | PASS |
|
|
|
PLM17-00610
| Other | 4/19/2017 | 4/19/2017 | 4/20/2017 9:55:38 AM | A | DONE |
|
|
first. Walk through with the plumber
|
PLM17-00557
| Water Heater Final | 4/19/2017 | 4/19/2017 | 4/19/2017 4:48:53 PM | P | PASS |
|
|
Call Bob ###-#### for access if there is nobody on site. Phone #: ###-#### Inspection requested via web by Ron Arnold
|
PLM17-01246
| Water Heater Final | 4/18/2017 | 4/19/2017 | 4/19/2017 4:31:07 PM | P | PASS |
|
|
Call Timothy prior ###-#### Phone #: ###-#### Inspection requested via web by curtis rowe
|
PLM17-01218
| Water and/or Sewer | 4/18/2017 | 4/19/2017 | 4/19/2017 3:51:20 PM | P | PASS |
|
|
Tech Contact is Russ McNally ###-#### Replace the water main from meter to connect to house supply, Phone #: ###-#### Phone #: ###-#### Inspection requested via web by Rusty Karel
|
MIS17-00122
| PLM-Conference | 4/19/2017 | 4/19/2017 | 4/19/2017 3:13:21 PM | P | PART |
|
|
Met with the homeowner. She will pull a permit and install faucets. No other trades involved.
|
PLM17-01242
| Plumbing Rough-in | 4/18/2017 | 4/19/2017 | 4/19/2017 3:10:50 PM | P | PART |
|
|
Kevin Phone #: ###-####. OK to cover exept the kitchen and master lavatory faucets.
|
PLM17-01024
| Plumbing Rough-in | 4/18/2017 | 4/19/2017 | 4/19/2017 2:41:58 PM | P | FAIL |
|
|
JOHN IS THE JOB CONTACT ###-####. THANKS. Phone #: ###-#### Inspection requested via web by BECCA DUMMER. DWV and water on the now bathroom ok to cover. 1. Increase the vent to meet cross sectional area. 2. Install a 1" double check valve for premise protection. 3. Increase the water size to 1" minimum below the existing gate valve and size the water system per plans. 4. Permanently remove the shower and remove plumbing where possible and permanently cap underground trap riser.
|
PLM17-01024
| Other | 4/18/2017 | 4/19/2017 | 4/19/2017 2:30:32 PM | P | PASS |
|
|
1:30 Mark
|
PLM17-00610
| Final | 4/18/2017 | 4/19/2017 | 4/19/2017 11:47:30 AM | A | FAIL |
|
|
After 8:30 please, thank you Phone #: ###-#### Inspection requested via web by Josh Kelley. 1. Provide and minimum 3" drip leg on the water heater gas feed. 2. Provide and approved access door to the water heater burner chamber. 3. Provide proof of a backflow certification to the RP carbonator feed. 4. Provide a minimum of 3 screws at each water heater flue joint. 5. Provide a serperate watter feed and shut-off to the chemical feeder at the mop sink. 6. Insatll all fixtures and seal to the wall or permanently cap supplies. 7. Provide a vent to the grease trap per manufactures instructions. (Outlet side) 8. Repair the leak on the ice maker water feed. 9. Trap and vent the ice maker inderect waste. 10. Use wye branch fittings, trap and vent the three compartment sink and all other fixtures more than 15 feet from the floor sink. Provide clean-outs per code. 11. Provide tempering valves at the restroom lavatory sinks. 12. The RP drain is backgrading on the ice machine next to the handsink.
|
PLM17-01240
| Sprinkler (Final) | 4/18/2017 | 4/19/2017 | 4/19/2017 9:40:32 AM | A | PASS |
|
|
Agustin Phone #: ###-####
|
PLM17-01190
| Final | 4/18/2017 | 4/19/2017 | 4/19/2017 9:11:46 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
PLM17-01209
| Water and/or Sewer | 4/18/2017 | 4/19/2017 | 4/19/2017 8:51:27 AM | A | PASS |
|
|
We have certified the backflow and are ready for the inspector to come back and finalize the inspection. Contact Andy Sifford : ###-#### Phone #: ###-#### Inspection requested via web by Rusty Karel
|