Inspections for the day of: Thursday, April 19, 2018.
Number of inspections: 20
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-01682 Final4/19/20184/19/20184/19/2018 4:03:00 PMPPASS
please call Craig ###-#### Phone #: ###-#### Inspection requested via web by Krista Boss
MEC18-01689 Conference4/19/20184/19/20184/19/2018 3:32:06 PMPDONE
3:00 PM
MEC18-00554 Final4/19/20184/19/20184/19/2018 3:10:54 PMPFAIL
AC:2018 Phone #: ###-#### Inspection requested via web by Gary Reeves - Need to witness duct blast
MEC18-00293 Final4/19/20184/19/20184/19/2018 3:10:37 PMPFAIL
AC:2018 Phone #: ###-#### Inspection requested via web by Gary Reeves - Need to witness duct blast
MEC18-00272 Rough-in4/19/20184/19/20184/19/2018 2:21:27 PMPPASS
inspection for the front entry and the bakery. Antonio will be your contact. Thank you! Phone #: ###-#### Inspection requested via web by Kim Adams
MEC18-01742 Final4/19/20184/19/20184/19/2018 2:00:03 PMPPASS
Inspection requested via web by Margie Rowe
MEC18-01559 Rough-in4/19/20184/19/20184/19/2018 1:27:56 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves - crawl not complete, need to seal metal duct work, need framing around B-vent
MEC18-01559 Pressure Test4/19/20184/19/20184/19/2018 1:27:00 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves - 20lb 5lb flue
MEC18-01560 Rough-in4/19/20184/19/20184/19/2018 1:26:21 PMPFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves - Need to seal metal duct, need framing around B-vent
MEC18-01560 Pressure Test4/19/20184/19/20184/19/2018 1:25:31 PMPPASS
Phone #: ###-#### Inspection requested via web by Gary Reeves - 20lb gas 5lb flue
MEC18-00735 Final4/19/20184/19/20184/19/2018 11:10:43 AMPFAIL
AC; 1905 Phone #: ###-#### Inspection requested via web by Gary Reeves - Need duct blast completed
MEC17-04910 Pressure Test4/18/20184/19/20184/19/2018 10:54:10 AMAPASS
CHRIS IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - 20lb gas pass on piping in wall in deli
MEC18-01688 Final4/19/20184/19/20184/19/2018 10:30:47 AMPPASS
MEC18-01688 Pressure Test4/16/20184/19/20184/19/2018 10:30:15 AMPPASS
INSTALLER AL ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - 20lb gas pass
MEC18-00828 Final4/18/20184/19/20184/19/2018 9:45:02 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Stegemann
MEC18-01670 Final4/13/20184/19/20184/19/2018 9:20:51 AMANR
SITE CONTACT: JOE WALSH ###-####
EXTEND GAS LINE FOR GRILL Phone #: ###-#### Inspection requested via web by Chris Field - Work isn't complete. I spoke with installer told him no pressure test needed, less than 10'ft of pipe. Need to bubble test joints. They are adding a open burner under an existing hood next to a fryer. I spoke with contractor and manager and let them know that and open flame closer than 16" to a fryer needs to have a shield in place that extends 8" above the top of the appliance thats the highest.
MEC16-03172 Mec-Aging Inspection4/19/20184/19/20184/19/2018 8:52:44 AM DONE
MEC16-03172 DOC - Permit Finaled4/19/20184/19/20184/19/2018 8:52:35 AMAPASS
MEC18-01610 Pressure Test4/18/20184/19/20184/19/2018 8:52:10 AMAPASS
RE-INSPECT PRESSURE WITNESS Phone #: ###-#### Inspection requested via web by Brandon Sorensen - 20lb gas pass
MEC17-03285 Mec-Aging Inspection4/19/20184/19/20184/19/2018 6:36:43 AM CANC