ELE07-01052
| Temporary Service | 4/2/2007 | 4/2/2007 | 4/2/2007 4:02:04 PM | P | PASS |
|
|
CONTACT JACK 9410621 t/s u/g new ok
|
ELE07-01076
| Electrical Rough-In | 4/1/2007 | 4/2/2007 | 4/2/2007 3:57:10 PM | P | FAIL |
|
|
Phone #: ###-#### corr. called 300.14 6" free length all locations, 110/14(B) loose crimp sleeves equip. grds, 300.4 (A)(1&(D) nail plates and 11/4" cables parallel to studs, 210.11(C)(2) all recepts in laundry shall be on laundry rm 20 amp circuit, 314.43 remove screw from inside of box in front soofit
|
ELE07-01076
| Permanent Service | 4/2/2007 | 4/2/2007 | 4/2/2007 3:22:18 PM | P | PASS |
|
|
Phone #: ###-#### p/s u/g new ok
|
ELE07-00540
| Rough-In Permanent Service | 4/2/2007 | 4/2/2007 | 4/2/2007 2:43:16 PM | P | FAIL |
|
|
jade; Phone #: ###-#### Internet Inspection Request from: Victoria Beall corr. fee due called left message, all violations not made and new ones created, 300.14 6" free conductor, 300.4(D) 11/4" cables parallel to studs, 300.15 boxes required all locations outside fixtures,110.3(A) replace broken box kit., 210.52(B) remove range hood, back entry recept and anything eles not allowed on SABC, 314.43 no screws or nails allowed in plastic boxes
|
ELE07-00540
| Permanent Service | 4/2/2007 | 4/2/2007 | 4/2/2007 2:36:08 PM | P | PASS |
|
|
jade; Phone #: ###-#### Internet Inspection Request from: Victoria Beall p/s o/h rec. ok
|
ELE07-00376
| Permanent Service | 3/28/2007 | 4/2/2007 | 4/2/2007 1:58:19 PM | P | PASS |
|
|
Jack, #4 GEC installed to water main, Hot h20 heater bonded around all fittings.Done! thanks Loren Phone #: ###-#### see added final
|
ELE07-00376
| Final | 4/2/2007 | 4/2/2007 | 4/2/2007 1:57:45 PM | P | PASS |
|
|
Jack, #4 GEC installed to water main, Hot h20 heater bonded around all fittings.Done! thanks Loren Phone #: ###-#### ok
|
ELE07-01077
| Rough-In Permanent Service | 4/2/2007 | 4/2/2007 | 4/2/2007 1:34:17 PM | P | PART |
|
|
9411710 walls ok no p/s meter needs ID
|
ELE07-00752
| Rough-In Permanent Service | 4/2/2007 | 4/2/2007 | 4/2/2007 12:55:27 PM | P | PASS |
|
|
On site journeyman - Gene ###-#### Thank you!! Phone #: ###-#### r/i p/s u/g new new ok all 4 units
|
ELE06-00461
| Final | 4/2/2007 | 4/2/2007 | 4/2/2007 12:13:18 PM | P | PASS |
|
|
marshall; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok
|
ELE06-04673
| Final | 3/30/2007 | 4/2/2007 | 4/2/2007 11:00:07 AM | A | FAIL |
|
|
Phone #: ###-#### corr. fee due called 410.8 &404.4 needs enclosed for closets, shower trims for wet, also install shelves and rods in closet for clearence check
|
ELE07-00833
| Electrical Rough-In | 3/30/2007 | 4/2/2007 | 4/2/2007 10:35:33 AM | A | FAIL |
|
|
Cover...Ryan; Phone #: ###-#### Internet Inspection Request from: Stacie Backus corr. do not cover called left message 300.4(A)(1)&(D) nail plates and 11/4", 250.32(B)(2) terminate GEC at neutral bus and install bond screw, 110.3(B) shall install main breaker per manu. instructions panel used as lighting panel, all 3 garages
|
ELE07-01075
| Electrical Rough-In | 3/30/2007 | 4/2/2007 | 4/2/2007 9:44:07 AM | A | NH |
|
|
bath and utility area, thank you Phone #: ###-#### x0000 notice posted
|
ELE07-01073
| Electrical Rough-In | 3/30/2007 | 4/2/2007 | 4/2/2007 9:33:45 AM | A | PASS |
|
|
paul ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith r/i ok
|
ELE07-00494
| Electrical Rough-In | 3/30/2007 | 4/2/2007 | 4/2/2007 8:55:09 AM | A | PASS |
|
|
Phone #: ###-#### r/i ok corrections made
|
ELE07-00764
| Final | 4/2/2007 | 4/2/2007 | 4/2/2007 8:40:36 AM | P | PASS |
|
|
Phone #: ###-#### ok
|
ELE07-00951
| Final | 3/31/2007 | 4/2/2007 | 4/2/2007 8:23:33 AM | A | PASS |
|
|
Phone #: ###-#### ok no card
|