ELE08-00743
| Rough-In Permanent Service | 4/2/2008 | 4/2/2008 | 4/2/2008 4:17:24 PM | P | FAIL |
|
|
JW is Ken Ikey. ###-#### Phone #: ###-#### Internet Inspection Request from: BRENDA HURST corr called note partial correction only p/s and both sub panels need clearence see posted notice
|
ELE07-03475
| Final | 4/1/2008 | 4/2/2008 | 4/2/2008 3:27:34 PM | P | FAIL |
|
|
Jack Phone #: ###-#### called 410.8 clearence for upstairs closet light, 110.3(B) use manufactures listed breakers only
|
ELE08-00591
| Electrical Rough-In | 4/2/2008 | 4/2/2008 | 4/2/2008 2:49:57 PM | P | PASS |
|
|
Rough and Cover Inspection. Please call Rowdy with questions at ###-####. Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe ok new sprinkler rm
|
ELE08-00221
| Final | 4/2/2008 | 4/2/2008 | 4/2/2008 2:22:28 PM | P | PASS |
|
|
pat Phone #: ###-#### ok card signed
|
ELE08-00773
| Electrical Rough-In | 4/2/2008 | 4/2/2008 | 4/2/2008 1:46:20 PM | P | FAIL |
|
|
mike Phone #: ###-#### Note: 1:00 pm called corr. posted 110.14(A) wires shall loop C W direction around screw terminals and shall be made up tight, 314.16 shall correct box fill 2 gang cutin in laundry rm
|
ELE08-00610
| Electrical Rough-In | 4/2/2008 | 4/2/2008 | 4/2/2008 1:01:59 PM | P | FAIL |
|
|
tom Note: grid - pool lights Phone #: ###-#### called corr & do not cover posted 680.26(C) shall use clamps listed for concrete alum not listed also raise re-bar 11/2" off of the grd
|
ELE04-04004
| Final | 4/2/2008 | 4/2/2008 | 4/2/2008 12:12:07 PM | P | PASS |
|
|
t/s ok for final
|
ELE08-00310
| Final | 4/1/2008 | 4/2/2008 | 4/2/2008 11:44:26 AM | A | NR |
|
|
Luke will be at job site wrapping up the grounding and would be best if possible to have the inspection after 9:30a.m. to allow time to 100% complete will grounding. If you need to contact Luke please call ###-####. Internet Inspection Request from: Mike TenHulzen contr called
|
ELE08-00466
| Electrical Rough-In | 4/1/2008 | 4/2/2008 | 4/2/2008 10:59:01 AM | A | PART |
|
|
Approval to cover warmtile heat matt in womens bathroom Phone #: ###-#### Internet Inspection Request from: Alan Lusk ok
|
ELE07-03907
| Final | 4/1/2008 | 4/2/2008 | 4/2/2008 10:00:13 AM | A | PASS |
|
|
St. Mark''s School Addition Final. Contact is Brian Cornell. Phone #: ###-#### Internet Inspection Request from: Richard Montgomery ok card signed
|
ELE04-01851
| DOC - Permit Expired | 4/2/2008 | 4/2/2008 | 4/2/2008 9:16:56 AM | A | PASS |
|
|
no action for final bld already finaled
|
ELE08-00775
| Electrical Rough-In | 4/1/2008 | 4/2/2008 | 4/2/2008 8:52:11 AM | A | PASS |
|
|
ed Phone #: ###-#### ok garage extension
|
ELE08-00761
| Electrical Rough-In | 4/1/2008 | 4/2/2008 | 4/2/2008 8:14:57 AM | A | PASS |
|
|
zahic Phone #: ###-#### ok
|