Inspections for the day of: Wednesday, April 2, 2008.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-00743 Rough-In Permanent Service4/2/20084/2/20084/2/2008 4:17:24 PMPFAIL
JW is Ken Ikey. ###-#### Phone #: ###-#### Internet Inspection Request from: BRENDA HURST corr called note partial correction only p/s and both sub panels need clearence see posted notice
ELE07-03475 Final4/1/20084/2/20084/2/2008 3:27:34 PMPFAIL
Jack Phone #: ###-#### called 410.8 clearence for upstairs closet light, 110.3(B) use manufactures listed breakers only
ELE08-00591 Electrical Rough-In4/2/20084/2/20084/2/2008 2:49:57 PMPPASS
Rough and Cover Inspection. Please call Rowdy with questions at ###-####. Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe ok new sprinkler rm
ELE08-00221 Final4/2/20084/2/20084/2/2008 2:22:28 PMPPASS
pat Phone #: ###-#### ok card signed
ELE08-00773 Electrical Rough-In4/2/20084/2/20084/2/2008 1:46:20 PMPFAIL
mike Phone #: ###-#### Note: 1:00 pm
called corr. posted 110.14(A) wires shall loop C W direction around screw terminals and shall be made up tight, 314.16 shall correct box fill 2 gang cutin in laundry rm
ELE08-00610 Electrical Rough-In4/2/20084/2/20084/2/2008 1:01:59 PMPFAIL
tom Note: grid - pool lights Phone #: ###-#### called corr & do not cover posted 680.26(C) shall use clamps listed for concrete alum not listed also raise re-bar 11/2" off of the grd
ELE04-04004 Final4/2/20084/2/20084/2/2008 12:12:07 PMPPASS
t/s ok for final
ELE08-00310 Final4/1/20084/2/20084/2/2008 11:44:26 AMANR
Luke will be at job site wrapping up the grounding and would be best if possible to have the inspection after 9:30a.m. to allow time to 100% complete will grounding. If you need to contact Luke please call ###-####. Internet Inspection Request from: Mike TenHulzen contr called
ELE08-00466 Electrical Rough-In4/1/20084/2/20084/2/2008 10:59:01 AMAPART
Approval to cover warmtile heat matt in womens bathroom Phone #: ###-#### Internet Inspection Request from: Alan Lusk
ok
ELE07-03907 Final4/1/20084/2/20084/2/2008 10:00:13 AMAPASS
St. Mark''s School Addition Final. Contact is Brian Cornell. Phone #: ###-#### Internet Inspection Request from: Richard Montgomery ok card signed
ELE04-01851 DOC - Permit Expired4/2/20084/2/20084/2/2008 9:16:56 AMAPASS
no action for final bld already finaled
ELE08-00775 Electrical Rough-In4/1/20084/2/20084/2/2008 8:52:11 AMAPASS
ed Phone #: ###-#### ok garage extension
ELE08-00761 Electrical Rough-In4/1/20084/2/20084/2/2008 8:14:57 AMAPASS
zahic Phone #: ###-#### ok