MEC12-03561
| Rough-in | 4/2/2013 | 4/2/2013 | 4/3/2013 9:17:14 AM | P | FAIL |
|
|
Rough In & Pressure Test. Thanks! Phone #: ###-#### >> Inspection requested via web by Frank Marturello 1) 1" clearance required at the B-Vent from water heater in garage ceiling and at wall above. 2)verify protection at B-Vent in 2nd floor wall. 3)dryer vent is disconnected at roof -support required. 4)insulate supply trunk in garage ceiling 5) 1-60# and 2-20# gas tests ok
|
PLM13-00459
| Final | 4/1/2013 | 4/2/2013 | 4/2/2013 9:21:50 AM | A | PASS |
|
|
DON Phone #: ###-#### final ok
|
PLM13-00740
| Water and/or Sewer | 4/1/2013 | 4/2/2013 | 4/2/2013 9:09:10 AM | A | PASS |
|
|
if you have any questions please call Mike ###-#### Thank you for your time, Maggie Phone #: ###-#### >> Inspection requested via web by Michael Abrao
|
PLM13-00740
| Final | 4/2/2013 | 4/2/2013 | 4/2/2013 9:08:53 AM | A | PASS |
|
|
if you have any questions please call Mike ###-#### Thank you for your time, Maggie Phone #: ###-#### >> Inspection requested via web by Michael Abrao
|
PLM13-00659
| Water Heater Final | 4/2/2013 | 4/2/2013 | 4/2/2013 8:50:34 AM | A | FAIL |
|
|
remove flex in relief line , hard pipe to exterior and recall for inspection
|