MEC18-01456
| Pressure Test | 4/2/2018 | 4/2/2018 | 4/2/2018 4:05:30 PM | P | CANC |
|
|
Call eric to coordinate @ ###-#### - Our guys will need to be there for the pressure test. Phone #: ###-#### Inspection requested via web by Kristin Dolan- not needed- unconditioned space
|
MEC18-01456
| Final | 4/2/2018 | 4/2/2018 | 4/2/2018 4:05:07 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kristin Dolan- furnace co ok
|
MEC17-01556
| Rough-in | 4/2/2018 | 4/2/2018 | 4/2/2018 3:49:41 PM | P | CANC |
|
|
if questions call Larry @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann- should have been pressure test
|
MEC17-01556
| Pressure Test | 4/2/2018 | 4/2/2018 | 4/2/2018 3:49:21 PM | P | PASS |
|
|
if questions call Larry @ ###-####. Phone #: ###-#### Inspection requested via web by Stacia Haumann- 20lb gas X 24 pass- 10 on 2nd floor, 4 on 3rd floor, 6 on 4th floor and 4 on 5th floor on csst piping in concrete floor thats sleeved
|
MEC18-01466
| Rough-in | 4/2/2018 | 4/2/2018 | 4/2/2018 3:17:15 PM | P | FAIL |
|
|
MEC AND FIREPL Phone #: ###-#### Inspection requested via web by Oleg Chervak- b vent insulation shields on fireplace flue and water heater flue need to be full height to roof to short for blow in insulation
|
MEC18-01466
| Pressure Test | 4/2/2018 | 4/2/2018 | 4/2/2018 3:16:05 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- 20lb gas pass
|
MEC18-01460
| Pressure Test | 4/2/2018 | 4/2/2018 | 4/2/2018 2:42:03 PM | P | FAIL |
|
|
Please call 1-###-#### 30 minutes before arrival. Thank you Phone #: ###-#### Inspection requested via web by chris mcdaniel- gauge wont zero out- need to provide 2 CO detectors by bedrooms
|
MEC18-01455
| Final | 4/2/2018 | 4/2/2018 | 4/2/2018 2:28:35 PM | P | PASS |
|
|
INSTALLER DAVID ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- furnace co ok
|
MEC18-01421
| Final | 4/2/2018 | 4/2/2018 | 4/2/2018 1:51:14 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bryan Palmer- furnace ac coil co ok
|
MEC18-00399
| Final | 4/2/2018 | 4/2/2018 | 4/2/2018 1:17:46 PM | P | PASS |
|
|
CHRIS IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER- gas piping ok- no pressure test needed soaped all connections- final ok
|
MEC17-02216
| Final | 3/30/2018 | 4/2/2018 | 4/2/2018 12:01:06 PM | A | PASS |
|
|
Final - call Luke Phone #: ###-#### Inspection requested via web by Brandon Sorensen- final ok- firedamper angles ok- revised prints at GC office
|
MEC18-00569
| Final | 4/1/2018 | 4/2/2018 | 4/2/2018 11:41:45 AM | P | CANC |
|
|
Bill with YMC will be the contact if any questions arise. If he is unavailable, you may reach out to me (Stephen Lee) at ###-####. Phone #: ###-#### Inspection requested via web by Stephen Lee-will do final inspection on YMC when permit is called in-
|
MEC18-01410
| Rough-in | 3/30/2018 | 4/2/2018 | 4/2/2018 10:40:15 AM | A | PASS |
|
|
duct seal inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- seal on duct ok- ok to insulate- ok to cover sauffect area front entry-
|
MEC18-01295
| Rough-in | 3/30/2018 | 4/2/2018 | 4/2/2018 9:34:24 AM | A | PASS |
|
|
Inspection requested via web by Aaron Alandt- R/I ok- no gas at this address all electric
|
MEC17-02499
| Mec-Aging Inspection | 4/2/2018 | 4/2/2018 | 4/2/2018 9:07:44 AM | | CANC |
|
|
no call will expire next time
|
MEC17-02900
| Mec-Aging Inspection | 4/2/2018 | 4/2/2018 | 4/2/2018 9:07:28 AM | | CANC |
|
|
no call- will expire next time
|
MEC18-00002
| Final | 3/30/2018 | 4/2/2018 | 4/2/2018 8:36:02 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette- electric furnace co ok
|