MEC19-04155
| Final | 4/16/2020 | 4/20/2020 | 4/20/2020 3:38:17 PM | P | FAIL |
|
|
She will be home all afternoon. She will not go to the back yard this time. Phone #: ###-#### Inspection requested via web by Brian Preece- electric airhandler coil heat pump ok- needs locking caps on all heat pump service ports (3)- send pic for reinspect
|
MIS20-00066
| MEC-Conference | 4/20/2020 | 4/20/2020 | 4/20/2020 3:16:02 PM | P | DONE |
|
|
Please follow up on this when you have an extra few minutes. Thanks Chad S.- emailed AJ early in morning no response- went by and talked to guy onsite to have AJ give us an update on getting engineer- Will check next week if no response
|
MEC20-01515
| Rough-in | 4/20/2020 | 4/20/2020 | 4/20/2020 3:05:09 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Joe Taylor- R/I ok- check equipment at final not set on R/I
|
MEC20-01221
| Rough-in | 4/20/2020 | 4/20/2020 | 4/20/2020 2:36:57 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak 1- gas gauge doesnt zero out- throw away 2- resubmit man j for approved equipment installed show payne with carrier installed 3- condensate drains both need 1/4" grade to outside per foot and use approved hangers drives not acceptable 4- b vent for w/h in garage will not have 1" clearance after sheetrock will be installed on ceiling and wall- need to firecaulk second floor at floor and attic in chase 5- return needs filter box installed
left notice back window
|
MEC20-01221
| Pressure Test | 4/20/2020 | 4/20/2020 | 4/20/2020 2:33:22 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Oleg Chervak- gauge doesnt xero out- throw gauge away
|
MEC19-05242
| Final | 4/20/2020 | 4/20/2020 | 4/20/2020 1:45:36 PM | P | PART |
|
|
Final inspection - Please contact Daryl prior to arrival. ###-#### Phone #: ###-#### Inspection requested via web by Commercial Coordinator- Temp occupancy ok- need to add 2 10" round dampers in OSA and Exhaust in unoccupied building and verify air balance to cfm shown on key note 2- Screening around units on roof need completed to verify access to doors are ok- talk with GC onsite
|
MEC20-01195
| Rough-in | 4/17/2020 | 4/20/2020 | 4/20/2020 1:16:07 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- crawl needs completed still installing- dryer duct can not run in 3 1/2 inch wall needs firred out or reroute
|
MEC20-01195
| Pressure Test | 4/17/2020 | 4/20/2020 | 4/20/2020 1:13:56 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- 20lb gas pass tagged meter location-5lb flue
|
MEC20-01258
| Rough-in | 4/20/2020 | 4/20/2020 | 4/20/2020 12:42:13 PM | P | PASS |
|
|
duct seal inspection Phone #: ###-#### Inspection requested via web by Brandon Sorensen- R/i ok- seal on duct ok- ok for insulation- ok for ceiling grid install- call in cover inspection when ready
|
MEC20-01329
| Rough-in | 4/17/2020 | 4/20/2020 | 4/20/2020 9:56:26 AM | A | CANC |
|
|
WALL ROUGH IN. DUSTY ARMSTRONG IS THE CONTACT Phone #: ###-#### >> Inspection requested via web by RM Mechanical Inspection cancelled from web by: RM Mechanical
|
MEC20-00762
| Final | 4/17/2020 | 4/20/2020 | 4/20/2020 9:38:06 AM | A | PASS |
|
|
Duct blast report is the the back of the literature rack next to water heater and commission stick is filled out on electrical panel in garage in sharpie Phone #: ###-#### Inspection requested via web by Randy Hart- final ok
|
MEC20-01515
| Rough-in | 4/16/2020 | 4/20/2020 | 4/20/2020 8:48:08 AM | A | FAIL |
|
|
Add pressure test Phone #: ###-#### Inspection requested via web by Joe Taylor 1- need city approved man j onsite 2- dryer vent is to long with fittings installed 35 feet max including fittings
|
MEC20-01515
| Pressure Test | 4/16/2020 | 4/20/2020 | 4/20/2020 8:43:55 AM | A | PASS |
|
|
Add rough in Phone #: ###-#### Inspection requested via web by Joe Taylor- 20lb gas pass tagged meter location
|
MEC20-01510
| Rough-in | 4/16/2020 | 4/20/2020 | 4/20/2020 8:43:23 AM | A | PASS |
|
|
ROBERT ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza- fireplace R/I ok
|
MEC18-04126
| Mec-Aging Inspection | 4/20/2020 | 4/20/2020 | 4/20/2020 7:52:48 AM | | FAIL |
|
|
contractor needs to schedule final inspection- permit has no been active since pressure test- permit will expire next aging if no activity-
|
MEC19-02800
| Mec-Aging Inspection | 4/20/2020 | 4/20/2020 | 4/20/2020 7:50:21 AM | | CANC |
|
|
permit expired
|
MEC19-02800
| DOC - Permit Expired | 4/20/2020 | 4/20/2020 | 4/20/2020 7:50:09 AM | A | PASS |
|
|
no calls no activity- permit expired
|
MEC19-04329
| Mec-Aging Inspection | 4/20/2020 | 4/20/2020 | 4/20/2020 7:49:26 AM | | FAIL |
|
|
contractor needs to schedule inspection- permit not active since issued- permit will expire next aging if no activity
|