BLD05-02018
| BLD-Framing/Rough-in | 4/20/2006 | 4/21/2006 | 4/21/2006 5:09:15 PM | P | CANC |
|
|
Scheduled by a contractor via Hello! on 4/20/2006 at 3:43:01 PM. Contact: ###-####. moved to monday.
|
BLD06-00327
| BLD-Footing | 4/21/2006 | 4/21/2006 | 4/21/2006 2:56:53 PM | P | PART |
|
|
john; Phone #: ###-#### Internet Inspection Request from: Cathy Chileswip
|
BLD05-02015
| BLD-Conference | 4/21/2006 | 4/21/2006 | 4/21/2006 2:12:55 PM | P | PART |
|
|
Scheduled by a contractor via Hello! on 4/21/2006 at 7:32:31 AM. Contact: ###-####. Need tech data on Hilti fire rated foam for application used on the 1 hr. floor ceiling assembly.
|
BLD05-02923
| BLD-Final | 4/21/2006 | 4/21/2006 | 4/21/2006 1:21:43 PM | P | PASS |
|
|
JOHN; Phone #: ###-#### Internet Inspection Request from: Cathy Chile. ok for perm once code enforcement has finaled. Also reviewed final aff. letter from special insp. co. ok.
|
BLD05-02766
| BLD-Framing/Rough-in | 4/15/2006 | 4/21/2006 | 4/21/2006 1:04:58 PM | A | FAIL |
|
|
mike i will be out of town this day, so my siding contractor will place plans and truss info on the job site. if you have any questions please call ###-####.vicki should be able to help you i hope thanks; Phone #: ###-#### Internet Inspection Request from: larry hobbs. Place additional studs at paralam were top plates were removed. Provide redwood shims or additional studs under ml beam ion basement. Provide header at doorway next to stairs. Fireblock doublewall by garage.
|
BLD06-00482
| BLD-Footing | 4/20/2006 | 4/21/2006 | 4/21/2006 12:25:43 PM | P | PART |
|
|
trudy; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. wip, set backs ok. basement walls backfilled with 4 inch drain rock.
|
BLD04-01559
| BLD-Aging Inspection | 4/21/2006 | 4/21/2006 | 4/21/2006 12:16:57 PM | | CANC |
|
|
|
BLD04-01559
| DOC - Permit Expired | 4/21/2006 | 4/21/2006 | 4/21/2006 12:16:47 PM | P | DONE |
|
|
|
BLD04-01487
| BLD-Aging Inspection | 4/21/2006 | 4/21/2006 | 4/21/2006 12:16:24 PM | | CANC |
|
|
|
BLD04-01487
| DOC - Permit Expired | 4/21/2006 | 4/21/2006 | 4/21/2006 12:16:15 PM | P | DONE |
|
|
|
BLD06-00903
| BLD-Other | 4/20/2006 | 4/21/2006 | 4/21/2006 10:55:10 AM | A | FAIL |
|
|
inspection of sewer plug (#512); Phone #: ###-#### Internet Inspection Request from: Adrian Marriage. wip, all cleanup not yet completed.
|
BLD05-03342
| BLD-Footing | 4/20/2006 | 4/21/2006 | 4/21/2006 10:44:25 AM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung. Noted to homeowner to get reinforcement off ground min 3 inches prior to placing conc.
|
BLD06-00629
| BLD-Framing/Rough-in | 4/20/2006 | 4/21/2006 | 4/21/2006 10:26:14 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 4/20/2006 at 2:24:38 PM. Contact: ###-####. All interior framing ok. Will need letter from architect noting that demissing walls are not required to be one hour. 9non seperated use)
|
BLD05-03005
| BLD-Final | 4/20/2006 | 4/21/2006 | 4/21/2006 9:35:40 AM | A | NR |
|
|
Phone #: ###-#### Internet Inspection Request from: Rita DeYoung. Needs plumbing final.
|
BLD05-03313
| BLD-Framing/Rough-in | 4/18/2006 | 4/21/2006 | 4/21/2006 8:54:54 AM | A | PASS |
|
|
Internet Inspection Request from: Carey Allen
|
BLD06-00138
| BLD-Aging Inspection | 4/21/2006 | 4/21/2006 | 4/21/2006 8:13:01 AM | | NR |
|
|
Still needs elec. final.
|