ELE08-00953
| Permanent Service | 4/21/2008 | 4/21/2008 | 4/21/2008 4:11:45 PM | P | PASS |
|
|
allen Phone #: ###-#### or ###-#### p/s o/h new ok
|
ELE08-00385
| Final | 4/21/2008 | 4/21/2008 | 4/21/2008 3:23:31 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Bryan Atkins ok
|
ELE08-00972
| Final | 4/21/2008 | 4/21/2008 | 4/21/2008 2:39:56 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: JENNY EMEL ok
|
ELE08-00103
| Final | 4/21/2008 | 4/21/2008 | 4/21/2008 1:56:22 PM | P | PASS |
|
|
allen Phone #: ###-#### ok
|
ELE08-00165
| Final | 4/21/2008 | 4/21/2008 | 4/21/2008 1:56:03 PM | P | PASS |
|
|
allen Phone #: ###-#### ok
|
ELE08-00505
| Final | 4/18/2008 | 4/21/2008 | 4/21/2008 11:46:09 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 4/18/2008 at 2:54:55 PM. Contact: ###-####. ok card signed
|
ELE08-00962
| Electrical Rough-In | 4/17/2008 | 4/21/2008 | 4/21/2008 11:13:48 AM | A | PASS |
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten ok
|
ELE08-00962
| Final | 4/21/2008 | 4/21/2008 | 4/21/2008 11:13:37 AM | A | PASS |
|
|
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten
|
ELE08-00983
| Final | 4/18/2008 | 4/21/2008 | 4/21/2008 10:55:02 AM | A | NR |
|
|
Chris Phone #: ###-#### needs p/s also needs time clock installed called
|
ELE08-00969
| Temporary Service | 4/18/2008 | 4/21/2008 | 4/21/2008 10:27:54 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe t/s u/g new ok
|
ELE08-00966
| Electrical Rough-In | 4/17/2008 | 4/21/2008 | 4/21/2008 10:07:52 AM | A | FAIL |
|
|
220v Spa Connection Phone #: ###-#### Internet Inspection Request from: Jenni Keller 110.3(A) replace damaged conductors at terminals ringed the wires, 352.26&356.26 over 360degrees of bends in PVC &LFNC, 356.1 &42 use listed fittings for LFNC not allowed to be glued to PVC coupling, 680.26(A)(5) bond all mwtal around spa as code noted states, check if PVC is schedule 80 called
|
ELE08-00904
| Electrical Rough-In | 4/18/2008 | 4/21/2008 | 4/21/2008 8:57:22 AM | A | FAIL |
|
|
Key to unlock padlock is in the back of the house in an old ammunissions box. Phone #: ###-#### Internet Inspection Request from: David Nelson called corr. 210.52(A) outlet wall space right of bath rm door in din rm 300.5 24" for uf in trench, 312.5 (C) needs conn for cables remove cables from raceways, also remove GEC from jbox and raceways, 334.15 protect exposed cables in basement, 250.148 grd bell boxes, note update permit for garage p/s and 1 rm also attach ELE to BLD permit
|