Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-00953 Permanent Service4/21/20084/21/20084/21/2008 4:11:45 PMPPASS
allen Phone #: ###-#### or ###-####
p/s o/h new ok
ELE08-00385 Final4/21/20084/21/20084/21/2008 3:23:31 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Bryan Atkins ok
ELE08-00972 Final4/21/20084/21/20084/21/2008 2:39:56 PMPPASS
Phone #: ###-#### Internet Inspection Request from: JENNY EMEL ok
ELE08-00103 Final4/21/20084/21/20084/21/2008 1:56:22 PMPPASS
allen Phone #: ###-#### ok
ELE08-00165 Final4/21/20084/21/20084/21/2008 1:56:03 PMPPASS
allen Phone #: ###-#### ok
ELE08-00505 Final4/18/20084/21/20084/21/2008 11:46:09 AMAPASS
Scheduled by a contractor via Hello! on 4/18/2008 at 2:54:55 PM. Contact: ###-####. ok card signed
ELE08-00962 Electrical Rough-In4/17/20084/21/20084/21/2008 11:13:48 AMAPASS
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten ok
ELE08-00962 Final4/21/20084/21/20084/21/2008 11:13:37 AMAPASS
ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten
ELE08-00983 Final4/18/20084/21/20084/21/2008 10:55:02 AMANR
Chris Phone #: ###-#### needs p/s also needs time clock installed called
ELE08-00969 Temporary Service4/18/20084/21/20084/21/2008 10:27:54 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe t/s u/g new ok
ELE08-00966 Electrical Rough-In4/17/20084/21/20084/21/2008 10:07:52 AMAFAIL
220v Spa Connection Phone #: ###-#### Internet Inspection Request from: Jenni Keller 110.3(A) replace damaged conductors at terminals ringed the wires, 352.26&356.26 over 360degrees of bends in PVC &LFNC, 356.1 &42 use listed fittings for LFNC not allowed to be glued to PVC coupling, 680.26(A)(5) bond all mwtal around spa as code noted states, check if PVC is schedule 80 called
ELE08-00904 Electrical Rough-In4/18/20084/21/20084/21/2008 8:57:22 AMAFAIL
Key to unlock padlock is in the back of the house in an old ammunissions box. Phone #: ###-#### Internet Inspection Request from: David Nelson called corr. 210.52(A) outlet wall space right of bath rm door in din rm 300.5 24" for uf in trench, 312.5 (C) needs conn for cables remove cables from raceways, also remove GEC from jbox and raceways, 334.15 protect exposed cables in basement, 250.148 grd bell boxes, note update permit for garage p/s and 1 rm also attach ELE to BLD permit