Inspections for the day of: Tuesday, April 21, 2009.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD07-02248 BLD-Aging Inspection4/21/20094/21/20094/29/2009 4:18:16 PM DONE
ESC08-00790 Random Inspection4/21/20094/21/20094/21/2009 3:39:18 PMPPART
ESC08-00789 Random Inspection4/21/20094/21/20094/21/2009 3:39:00 PMPPART
BLD08-01993 BLD-Conference4/21/20094/21/20094/21/2009 3:38:45 PMPPART
1003.5 Elevation change.
Where changes in elevation of less than 12 inches (305 mm) exist in the means of egress, sloped surfaces shall be used. Where the slope is greater than one unit vertical in 20 units horizontal (5-percent slope), ramps complying with Section 1010 shall be used. Where the difference in elevation is 6 inches (152 mm) or less, the ramp shall be equipped with either handrails or floor finish materials that contrast with adjacent floor finish materials.
Exceptions:
1. A single step with a maximum riser height of 7 inches (178 mm) is permitted for buildings with occupancies in Groups F, H, R-2 and R-3 and Groups S and U at exterior doors not required to be accessible by Chapter 11.
BLD08-01994 BLD-Conference4/21/20094/21/20094/21/2009 3:38:20 PMPPART
1003.5 Elevation change.
Where changes in elevation of less than 12 inches (305 mm) exist in the means of egress, sloped surfaces shall be used. Where the slope is greater than one unit vertical in 20 units horizontal (5-percent slope), ramps complying with Section 1010 shall be used. Where the difference in elevation is 6 inches (152 mm) or less, the ramp shall be equipped with either handrails or floor finish materials that contrast with adjacent floor finish materials.
Exceptions:
1. A single step with a maximum riser height of 7 inches (178 mm) is permitted for buildings with occupancies in Groups F, H, R-2 and R-3 and Groups S and U at exterior doors not required to be accessible by Chapter 11.
BLD08-01992 BLD-Conference4/21/20094/21/20094/21/2009 3:37:52 PMPPART
1003.5 Elevation change.
Where changes in elevation of less than 12 inches (305 mm) exist in the means of egress, sloped surfaces shall be used. Where the slope is greater than one unit vertical in 20 units horizontal (5-percent slope), ramps complying with Section 1010 shall be used. Where the difference in elevation is 6 inches (152 mm) or less, the ramp shall be equipped with either handrails or floor finish materials that contrast with adjacent floor finish materials.
Exceptions:
1. A single step with a maximum riser height of 7 inches (178 mm) is permitted for buildings with occupancies in Groups F, H, R-2 and R-3 and Groups S and U at exterior doors not required to be accessible by Chapter 11.
BLD08-02350 BLD-Energy code compliance4/21/20094/21/20094/21/2009 3:15:28 PMPPASS
Phone #: ###-####
ESC08-00736 Random Inspection4/21/20094/21/20094/21/2009 3:14:59 PMPPART
BLD09-00018 BLD-Framing/Rough-in4/20/20094/21/20094/21/2009 11:24:22 AMAPASS
andy -###-#### - this is for unit 530 - this is not part of the plan mod
BLD09-00401 BLD-Framing/Rough-in4/20/20094/21/20094/21/2009 12:00:00 AMACANC
Greg Phone #: ###-####