ELE11-00303
| ELE-Aging Inspection | 4/21/2011 | 4/21/2011 | 4/25/2011 3:19:03 PM | | DONE |
|
|
see final
|
ELE11-00286
| ELE-Aging Inspection | 4/21/2011 | 4/21/2011 | 4/25/2011 3:17:17 PM | | DONE |
|
|
still under construction
|
GCE11-00042
| GCE-Final | 4/20/2011 | 4/21/2011 | 4/22/2011 1:34:33 PM | A | PASS |
|
|
FinalKen @ ###-#### ok final
|
GCE11-00042
| GCE-Permanent Service | 4/20/2011 | 4/21/2011 | 4/22/2011 11:36:15 AM | A | CANC |
|
|
Perm ServiceKen @ ###-####Call in advance see 4/22/11 response
|
ELE11-00735
| Temporary Service | 4/21/2011 | 4/21/2011 | 4/21/2011 4:02:20 PM | P | FAIL |
|
|
Service inspection request-contact is Jake Chouinard ###-#### Phone #: ###-#### >> Inspection requested via web by Scott Campbell met with contractor, gave corrections, add bond bushings, phase tape and color, length of neutral conductor for parallel conductors, fuse sizes
|
ELE11-00785
| Rough-In Permanent Service | 4/21/2011 | 4/21/2011 | 4/21/2011 2:30:43 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Emmet Bushman called, left correction notice, NEC 250.86 shall provide grounding for metal boxes, 330.30(B) shall secure mc cable within 12" of box
|
ELE11-00772
| Electrical Rough-In | 4/21/2011 | 4/21/2011 | 4/21/2011 12:24:00 PM | P | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by kendall bender called, left correction notice, NEC 210.8(B)(5) receptacles within 6' of sink shall be gfci protected, 300.11(B) (C) shall not support cable wiring from other cables, BCC shall not cover any wiring prior to inspection- no devices installed
|
GCE11-00045
| GCE-Rough-In | 4/20/2011 | 4/21/2011 | 4/21/2011 10:02:43 AM | A | PASS |
|
|
Rough-InPat @ ###-####Call in advance ri ok
|
ELE10-01493
| Final | 4/20/2011 | 4/21/2011 | 4/21/2011 9:13:20 AM | A | CANC |
|
|
Van please call 30 min before going out Phone #: ###-#### see ri
|
ELE10-01493
| Electrical Rough-In | 4/21/2011 | 4/21/2011 | 4/21/2011 9:05:13 AM | A | PART |
|
|
Van please call 30 min before going out Phone #: ###-#### ok cover upstairs and entry ceiling, need to see fireplace wall
|
ELE11-00453
| Final | 4/20/2011 | 4/21/2011 | 4/21/2011 8:52:05 AM | A | PART |
|
|
tim Phone #: ###-#### signed t/o card pending office furniture inspection
|
ELE11-00763
| Electrical Rough-In | 4/20/2011 | 4/21/2011 | 4/21/2011 8:16:31 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dan Rohl ri ok
|
ELE11-00685
| Final | 4/20/2011 | 4/21/2011 | 4/20/2011 11:32:57 AM | A | CANC |
|
|
This is a final inspection please. We would like an 8:00 am inspection if possible. Contact is Bob Callahn. Please call Bob when you are on your way to the site. Thank you so much. Phone #: ###-#### >> Inspection requested via web by Laura Longshaw Inspection cancelled from web by: Laura Longshaw
|