Inspections for the day of: Friday, April 21, 2017.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBen Livingston
TitleMEC-COM/RES INSPECTOR
Phone #576-1208
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM17-01238 Water Heater Final4/20/20174/21/20174/21/2017 3:14:41 PMPFAIL
Home is vacant so homeowner Mary will be meeting you there, give her a 15 minute pre-call at ###-####. Available after 10:30am Phone #: ###-#### Inspection requested via web by Andrea Grigsby
gas line needs drip leg, vent piping needs 3 screws on all connections.
MEC17-01445 Final4/20/20174/21/20174/21/2017 3:01:56 PMPPASS
Please meet installer Brad onsite. Please go later in PM to allow completion of project. Phone #: ###-#### Inspection requested via web by Rick Montgomery
MEC16-03000 Final4/21/20174/21/20174/21/2017 2:19:01 PMPPART
Request for final inspection. Please contact job lead Daryl 412--6637 with any questions or concerns. Phone #: ###-#### Inspection requested via web by Heather Gransbery
3rd floor staff only room by chase needs a duct access door by fire smoke damper, 4th floor missing SFD label at chase, final with balance report
MEC17-01388 Rough-in4/21/20174/21/20174/21/2017 1:55:31 PMPPASS
Phone #: ###-#### Inspection requested via web by Ed Ables
MEC17-01390 Rough-in4/21/20174/21/20174/21/2017 1:54:48 PMPPASS
Phone #: ###-#### Inspection requested via web by Ed Ables
MEC17-01410 Rough-in4/21/20174/21/20174/21/2017 1:21:12 PMPPASS
ken litz ###-#### Inspection requested via web by william kerwin
need protection post at final
MEC16-01330 Mec-Aging Inspection4/21/20174/21/20174/21/2017 11:04:47 AM CANC
MEC16-01330 DOC - Permit Expired4/21/20174/21/20174/21/2017 11:04:41 AMPPASS
MEC17-01364 Final4/19/20174/21/20174/21/2017 11:03:56 AMAFAIL
Phone #: ###-#### Inspection requested via web by Marisa Hone
need flue pressure test
MEC17-01451 Rough-in4/20/20174/21/20174/21/2017 10:32:44 AMAFAIL
Phone #: ###-#### Inspection requested via web by Teresa Costello
fresh air is undersized, basement dryer vent is to long to meet code, dryer vent 1st floor needs wall furred out to meet code,
condensate piping in walls needs to be approved material
MEC17-01451 Pressure Test4/20/20174/21/20174/21/2017 10:30:39 AMAPART
Phone #: ###-#### Inspection requested via web by Teresa Costello
5l flue okay,
gas pressure under 20lb
MEC17-01407 Final4/20/20174/21/20174/21/2017 9:23:52 AMAPASS
Lawrence Johnson is the contact on this...if possible can you perform this inspection between 8-10 am Phone #: ###-#### Inspection requested via web by Marisa Hone