Inspections for the day of: Tuesday, April 22, 2003.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJoe Ray
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE03-00392 Final4/21/20034/22/20034/22/2003 12:00:00 AMACANC
We installed a DP 50amp GFCI breaker in the garage panel, ran a 3/4" emt into crawlspace, changed to 3/4" smurf thru crawlspace, changed to 3/4" pvc #80 as we exited the foundation vent up to the RT Disconnect on the back of the house. We ran 1" pvc #80 from this disc. to the hot tub, changed to 1" LTNM flex inside the tub. We pulled #8 thhn's from panel to disc., and pulled #6 thhn's from disc. to tub. There is an existing outdoor receptacle to left of the sliding glass door(right around corner).; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
ELE03-01154 Rough-In Permanent Service4/21/20034/22/20034/22/2003 12:00:00 AMAPASS
###-#### john p/s ug n ok 4/22/2003 10:14:42 AM
ELE03-01142 Final4/21/20034/22/20034/22/2003 12:00:00 AMAPASS
We installed a DP 50 amp GFCI bkr. in the garage panel, ran 3/4" emt into crawlspace, changed to smurf thru crawlspace, changed to pvc #80 as we exited crawlspace up to RT disc. on back of house. Pulled in #8 thhn's. We ran 1" pvc #80 from disc. to hot tub, changed to 1" LTNM flex inside tub and pulled in #6 thhn's. There is an existing outdoor 120volt recept. just around corner to left of sliding glass door.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
ELE03-01157 Electrical Rough-In4/21/20034/22/20034/22/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 4/21/2003 at 12:34:09 PM. Contact: ###-####. walls only r/i ok 4/22/2003 9:52:40 AM
ELE03-00571 Final4/21/20034/22/20034/22/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 4/21/2003 at 9:38:09 PM. Contact: ###-####.
ELE03-01171 Final4/22/20034/22/20034/22/2003 12:00:00 AMPPASS
Phone #: ###-#### Internet Inspection Request from: Andy Rose
ELE03-01126 Electrical Rough-In4/22/20034/22/20034/22/2003 12:00:00 AMPPASS
###-#### jesse slab under ground ok 4/22/2003 2:53:27 PM
ELE03-00432 Final4/22/20034/22/20034/22/2003 12:00:00 AMPPASS
###-####
ELE02-02624 Final4/22/20034/22/20034/22/2003 12:00:00 AMPPASS
brett; Phone #: ###-#### Internet Inspection Request from: Annette Moore
ELE02-02534 Final4/22/20034/22/20034/22/2003 12:00:00 AMPPASS
brett; Phone #: ###-#### Internet Inspection Request from: Annette Moore