Inspections for the day of: Monday, April 22, 2019.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorTom Saunders
TitleELE-INSPECTOR
Phone #208-794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE19-00452 Final4/22/20194/22/20194/22/2019 2:46:55 PMPNH
Phone #: ###-#### Inspection requested via web by David McClellan..no acess...contractor will reschedule...GC responsible
ELE18-04627 Final4/22/20194/22/20194/22/2019 2:23:53 PMPPASS
Garage Code 2018 Phone #: ###-#### Inspection requested via web by Darryn Coburn..ok to final
ELE19-00672 Electrical Rough-In4/22/20194/22/20194/22/2019 1:37:45 PMPPASS
Need treadmill walls inspected for cover, Jason will be on site Phone #: ###-#### Inspection requested via web by robert feller...
3 sections ok to cover...pvc pipe to boxes...equipment ground will be ran...circuit per outlet
ELE19-01418 Permanent Service4/19/20194/22/20194/22/2019 1:15:54 PMPPASS
1:00 PM Inspection Phone #: ###-#### Inspection requested via web by Alan Lusk...
new 200 A all-in-one..existing panel sub panel
p/s u/g reconnect ok
ELE19-01418 Electrical Rough-In4/22/20194/22/20194/22/2019 1:14:21 PMPPASS
1:00 PM Inspection Phone #: ###-#### Inspection requested via web by Alan Lusk...
underground for tub ok to cover
discussed clearances, patio outlet location ok, and disconnect location ok
ELE19-01076 Electrical Rough-In4/22/20194/22/20194/22/2019 12:39:43 PMPPASS
Underground for carwash Phone #: ###-#### Inspection requested via web by Stan Woodward...ok to cover
ELE19-01067 Final4/19/20194/22/20194/22/2019 12:33:19 PMAPASS
Please call Nick when you are on your way. Number above.
Thank you, Greg Phone #: ###-#### Inspection requested via web by Greg Idsinga...
ok to final
ELE18-04502 Final4/20/20194/22/20194/22/2019 10:50:45 AMPCANC
call so i can get you in Phone #: ###-#### >> Inspection requested via web by Eddy Udry Inspection cancelled from web by: Eddy Udry
ELE18-02716 Final4/21/20194/22/20194/22/2019 9:53:22 AMAPASS
Greg is the contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker...
job complete...no card onsite..ok to final
ELE19-00929 Conference4/16/20194/22/20194/22/2019 9:08:51 AMAPASS
call for access Nathan-###-####...
discussed replacing 200A panel with new 200A...existing meterbase needs addressed-expansion joint added and new meterbase or reducing washers...homeowner competent in work
ELE18-04742 Final4/19/20194/22/20194/22/2019 8:13:22 AMAPASS
Please contact Tracy ###-####2 with any questions or concerns. Phone #: ###-#### Inspection requested via web by Todd Hall...
corrections made...ok to final
ELE19-01284 Conference4/19/20194/22/20194/22/2019 7:53:38 AMAPASS
Phone #: ###-#### Inspection requested by Steven M Bandkau Jr...7:30 AM first thing....
discussed wiring of shop...seperate service from house 200A...uffer ground verified by picture...homeowner competent to do work