Inspections for the day of: Monday, April 23, 2007.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-00046 Electrical Rough-In4/23/20074/23/20074/23/2007 4:14:30 PMPNR
Above ceiling inspection please. Thank you
Phone #: ###-#### Internet Inspection Request from: Laura Longshaw
300.11 wires for support of cables , high and low voltage, 400.8 no cords above ceiling time clock above panels
ELE07-01217 Electrical Rough-In4/23/20074/23/20074/23/2007 3:37:29 PMPPART
bruce - panel insp. ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith sub panels ok
ELE06-04726 Final4/23/20074/23/20074/23/2007 3:02:26 PMPPASS
Final inspection please call Steve Ruter Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson
ok card signed
ELE07-01430 Electrical Rough-In4/23/20074/23/20074/23/2007 2:30:21 PMPPASS
###-#### dustin ok
ELE07-01380 Final4/23/20074/23/20074/23/2007 2:04:48 PMPPASS
Electrician - Tony Norton ###-####
Resident - John and Pam Wall ###-#### Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer
ELE07-00993 Final4/23/20074/23/20074/23/2007 1:32:50 PMPFAIL
david; Phone #: ###-#### Internet Inspection Request from: Victoria Beall could not locate, called no response, shall be called in for t/s not final
ELE07-00639 Final4/20/20074/23/20074/23/2007 12:52:36 PMPPASS
Call Bobby Langer ###-#### Final inspection Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson
ok card signed
ELE07-00639 Electrical Rough-In4/23/20074/23/20074/23/2007 12:52:17 PMPPASS
Call Bobby Langer ###-#### Final inspection Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson
ceilings ok
ELE07-01406 Final4/20/20074/23/20074/23/2007 10:14:01 AMAFAIL
circuit for water heater in basement, upgrade service. Thank you. Kim Furhman should be home, ###-####
Phone #: ###-#### x0000 Internet Inspection Request from: BRIAN KEITH
corr. fee due, called 250.104 shall bond around anything that isolates metal piping, 250.24 all grds and bonds shall be at main p/s not sub panels , isolate grds and neutrals at sub pnaels, remove spliced grd wire at subpanel, BCC no violations retained , wiring for hot tub shall meet NEC 680, connectors for all cables old subpanel garage, circuit directory be specific, 334.15 protect new wiring in basement, 300.4 nail plates and 11/4"
ELE07-01077 Final4/20/20074/23/20074/23/2007 8:41:42 AMAPASS
chris; Phone #: ###-#### Internet Inspection Request from: Stacie Backus
ok card signed
ELE07-01077 Electrical Rough-In4/23/20074/23/20074/23/2007 8:41:31 AMAPASS
chris; Phone #: ###-#### Internet Inspection Request from: Stacie Backus
ceiling ok
ELE07-01393 Electrical Rough-In4/20/20074/23/20074/23/2007 12:00:00 AMACANC
Craig; Phone #: ###-#### Internet Inspection Request from: Stacie Backus