Inspections for the day of: Wednesday, April 23, 2008.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01011 Final4/23/20084/23/20084/23/2008 4:00:53 PMPPASS
brandon Phone #: ###-#### note: call for access called contractor, ok to final
ELE08-00183 ELE-Aging Inspection4/23/20084/23/20084/23/2008 3:21:19 PM DONE
see final
ELE08-00183 Final4/23/20084/23/20084/23/2008 3:20:19 PMPPASS
looked at sign, ok to final
ELE08-00984 Permanent Service4/23/20084/23/20084/23/2008 2:18:21 PMPPASS
Adam; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt p/s u/g rec ok
ELE08-00814 Rough-In Permanent Service4/23/20084/23/20084/23/2008 1:53:24 PMPFAIL
Scheduled by a contractor via Hello! on 4/23/2008 at 7:53:49 AM. Contact: ###-####. called, left correction notice, BCC shall install mains for service, shall final bld for core and shall, shall post address, NEC 348.30(A) shall strap fmc (mc cable) within 12" of panel, 110.26 shall provide work space in front of service, 110.26(F)(1)(b) there shall be no foreign piping over panel
ELE08-00815 Rough-In Permanent Service4/23/20084/23/20084/23/2008 12:50:42 PMPFAIL
Scheduled by a contractor via Hello! on 4/23/2008 at 7:53:00 AM. Contact: ###-####. called contractor, left correction notice, BCC shall install mains for service, shall final core and shell BLD permit, shall post address, NEC 362.30 shall securely fasten ent within 3' of termination, 110.26 shall provide workspace in front of service
ELE08-00984 Final4/22/20084/23/20084/23/2008 10:23:53 AMACANC
200amp service upgrade. Should be ready for inspection just before lunch time. Thank you! Phone #: ###-#### Internet Inspection Request from: Adam Staigle contractor wanted to call for pm
ELE08-01017 Electrical Rough-In4/22/20084/23/20084/23/2008 10:23:05 AMAPASS
george Phone #: ###-#### ric ok
ELE08-00007 Electrical Rough-In4/21/20084/23/20084/23/2008 9:48:11 AMAPASS
bonding for spa Phone #: ###-#### Internet Inspection Request from: Jari Rivers spa bond only ok, no u/g seen for conduit
ELE08-01011 Rough-In Permanent Service4/22/20084/23/20084/23/2008 8:54:05 AMAPASS
JW is Fred, ###-####. Permanent service too, please. Phone #: ###-#### Internet Inspection Request from: BRENDA HURST ric ok, p/s u/g n ok
ELE08-00900 Electrical Rough-In4/23/20084/23/20084/23/2008 8:23:56 AMAPASS
Scheduled by a contractor via Hello! on 4/23/2008 at 7:27:37 AM. Contact: ###-####. walls only ric ok, hard lids not ready, will have dropped ceiling
ELE07-02790 Electrical Rough-In4/22/20084/23/20084/23/2008 7:51:18 AMAPASS
swimming pool potting inspection Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe potting ok, 2 lights only
ELE08-00984 Final4/22/20084/23/20084/22/2008 9:10:31 PMPCANC
200 amp service upgrade. Phone #: ###-#### Internet Inspection Request from: Adam Staigle Inspection cancelled from web by: Adam Staigle