Inspections for the day of: Monday, April 23, 2012.
Number of inspections: 13
Percentage of inspections complete: 92 %
Percentage of inspections not complete: 8 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC11-00609 General Inspection4/16/20124/16/2012   
ELE09-00765 ELE-Aging Inspection4/23/20124/23/20124/23/2012 3:34:31 PM PASS
still under construction
ELE12-00765 Temporary Service4/23/20124/23/20124/23/2012 3:33:25 PMPPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov t/s u/g ok
ELE12-00310 Final4/23/20124/23/20124/23/2012 1:30:31 PMPPASS
GARAGE CODE 10020, THIS IS A MODEL SO IT HAS FURNITURE PLACED, IT ISNT IN THE WAY BUT IF YOU WANT HELP TO MOVE STUFF CALL ME AND I WILL MEETN YOU THERE. THANKS, BILL Phone #: ###-#### >> Inspection requested via web by Bob Glenn final ok
ELE12-00836 Permanent Service4/20/20124/23/20124/23/2012 12:55:03 PMPPASS
pool boonding inspection Phone #: ###-#### >> Inspection requested via web by Kelly Felin rough-in ok cover pool equipment bonding conductor,2-wet niche luminaires. No provisions for bonding of metal ladder
GCE12-00036 GCE-Final4/20/20124/23/20124/23/2012 10:26:17 AMAPASS
(Mandatory Inspection)

Carl @ ###-####
Requested an AM inspection
He doesn't have a cell phone, but will be there @ 8:00 AM and will wait for the inspector.
final ok
ELE12-00768 Electrical Rough-In4/20/20124/23/20124/23/2012 10:09:28 AMAPASS
lock box code is 7012. Any problems give me a call. Thanx Clay ###-#### Phone #: ###-#### >> Inspection requested via web by Clay Morgan rough-in ok cover
ELE12-00810 Electrical Rough-In4/20/20124/23/20124/23/2012 9:51:33 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Barbara Szurgot rough-in ok cover kitchen remodel
ELE12-00835 Final4/20/20124/23/20124/23/2012 9:39:19 AMANR
Addition of main disconnect on house. Phone #: ###-#### >> Inspection requested via web by Lars Johnson
ELE12-00835 Permanent Service4/23/20124/23/20124/23/2012 9:37:53 AMAFAIL
Permanent service NEC 250.32 Requires four wire system from disconect on outside of house to indoor panel, with separation of grounds and neutrals
ELE12-00835 Electrical Rough-In4/23/20124/23/20124/23/2012 9:17:32 AMAPASS
rough-in ok cover ground rods- pour concrete
ELE12-00007 Final4/20/20124/23/20124/23/2012 8:40:58 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Phil Baker final ok
ELE12-00836 Final4/20/20124/23/20124/20/2012 2:06:53 PMPCANC
Pool Bonding Inspection Phone #: ###-#### >> Inspection requested via web by Kelly Felin Inspection cancelled from web by: Kelly Felin