ELE12-02100
| ELE-Aging Inspection | 4/23/2014 | 4/23/2014 | 4/24/2014 3:23:39 PM | | DONE |
|
|
spoke with Greg and he will call it in
|
ELE11-02838
| Final | 4/23/2014 | 4/23/2014 | 4/23/2014 3:43:28 PM | P | FAIL |
|
|
The key to the door is in meter box on back patio please put key back when finished thank you Phone #: ###-#### >> Inspection requested via web by cory carman 210.8(A)(1) bath receptacles need to be GFCI protected. 314.20- tile backsplash needs box extensions in bath and kitchen. 250.32- ground rod at garage panel. 250.53 (D)(2) add 2nd ground rod at house. 410.10(D) shower needs recessed trim rated for damp location. Install lockoffs on furnace and dishwasher breakers. garage u.ground conduit has no connector and needs to be strapped.
|
ELE14-00950
| Electrical Rough-In | 4/23/2014 | 4/23/2014 | 4/23/2014 1:43:00 PM | P | PASS |
|
|
Someone will be there. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan rough in ok to cover mstr. bdrm, bath and closet and liv.rm wall
|
ELE13-02833
| Final | 4/23/2014 | 4/23/2014 | 4/23/2014 12:58:27 PM | P | PASS |
|
|
Please call Byron with any problems Phone #: ###-#### >> Inspection requested via web by Rhonda Zamagni final ok corrections made
|
ELE09-02323
| ELE-Aging Inspection | 4/23/2014 | 4/23/2014 | 4/23/2014 11:40:40 AM | | CANC |
|
|
still under const.
|
ELE09-00765
| DOC - Permit Expired | 4/23/2014 | 4/23/2014 | 4/23/2014 10:45:34 AM | A | PASS |
|
|
no activity on job, ok doc expire
|
ELE13-02057
| Electrical Rough-In | 4/22/2014 | 4/23/2014 | 4/23/2014 9:56:01 AM | A | PASS |
|
|
Ceiling Cover Phone #: ###-#### >> Inspection requested via web by Buster Bowen rough in ok to cover first floor ceiling
|
GCE14-00052
| GCE-Rough-In | 4/22/2014 | 4/23/2014 | 4/23/2014 9:18:24 AM | A | PASS |
|
|
louis ###-#### Bonding and potting gate*5551 bonding and u.ground 11/4 conduit ok
|
GCE13-00191
| GCE-Rough-In | 4/22/2014 | 4/23/2014 | 4/23/2014 8:58:25 AM | A | DONE |
|
|
Don ###-#### or Brian ###-#### conference with don on receptacle placement and location of fire walls and switch locations to meet code. conclusion: they will meet 210.60 but don't agree on 210.70(A) (2) for entry from patio area. Owner says occupants won't be outside after dark anyway.
|