Inspections for the day of: Wednesday, April 23, 2014.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRex Boyles
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02100 ELE-Aging Inspection4/23/20144/23/20144/24/2014 3:23:39 PM DONE
spoke with Greg and he will call it in
ELE11-02838 Final4/23/20144/23/20144/23/2014 3:43:28 PMPFAIL
The key to the door is in meter box on back patio please put key back when finished thank you Phone #: ###-#### >> Inspection requested via web by cory carman 210.8(A)(1) bath receptacles need to be GFCI protected. 314.20- tile backsplash needs box extensions in bath and kitchen. 250.32- ground rod at garage panel. 250.53 (D)(2) add 2nd ground rod at house. 410.10(D) shower needs recessed trim rated for damp location. Install lockoffs on furnace and dishwasher breakers. garage u.ground conduit has no connector and needs to be strapped.
ELE14-00950 Electrical Rough-In4/23/20144/23/20144/23/2014 1:43:00 PMPPASS
Someone will be there. Thanks Phone #: ###-#### >> Inspection requested via web by Clay Morgan rough in ok to cover mstr. bdrm, bath and closet and liv.rm wall
ELE13-02833 Final4/23/20144/23/20144/23/2014 12:58:27 PMPPASS
Please call Byron with any problems Phone #: ###-#### >> Inspection requested via web by Rhonda Zamagni final ok corrections made
ELE09-02323 ELE-Aging Inspection4/23/20144/23/20144/23/2014 11:40:40 AM CANC
still under const.
ELE09-00765 DOC - Permit Expired4/23/20144/23/20144/23/2014 10:45:34 AMAPASS
no activity on job, ok doc expire
ELE13-02057 Electrical Rough-In4/22/20144/23/20144/23/2014 9:56:01 AMAPASS
Ceiling Cover Phone #: ###-#### >> Inspection requested via web by Buster Bowen rough in ok to cover first floor ceiling
GCE14-00052 GCE-Rough-In4/22/20144/23/20144/23/2014 9:18:24 AMAPASS
louis ###-#### Bonding and potting gate*5551 bonding and u.ground 11/4 conduit ok
GCE13-00191 GCE-Rough-In4/22/20144/23/20144/23/2014 8:58:25 AMADONE
Don ###-#### or Brian ###-#### conference with don on receptacle placement and location of fire walls and switch locations to meet code. conclusion: they will meet 210.60 but don't agree on 210.70(A) (2) for entry from patio area. Owner says occupants won't be outside after dark anyway.