ELE18-00805
| Electrical Rough-In | 4/20/2018 | 4/23/2018 | 4/23/2018 2:52:40 PM | P | PART |
|
|
We need a Ceiling Border cover inspection. Dave is the site contact. Thank you! Phone #: ###-#### Inspection requested via web by Stacie Tasker large open office area only borders only Ceiling only ok
|
ELE18-00637
| Electrical Rough-In | 4/17/2018 | 4/23/2018 | 4/23/2018 2:14:49 PM | P | PASS |
|
|
After 1 pm Phone #: ###-#### Inspection requested via web by Steve Hanchett Back area of basement only ok to cover
|
ELE16-02746
| Electrical Rough-In | 4/23/2018 | 4/23/2018 | 4/23/2018 1:51:52 PM | P | PASS |
|
|
Corridor 2 North Corridor 3 North rough ceiling grid inspection to cover Phone #: ###-#### Inspection requested via web by Kenneth Chapman Ceiling only area listed ok to cover
|
ELE18-01375
| Electrical Rough-In | 4/23/2018 | 4/23/2018 | 4/23/2018 1:41:57 PM | P | PART |
|
|
Electrical Rough-in Phone #: ###-#### Inspection requested via web by Kendra Lanham Do not coever laundry room. Overfilled box( Exhisting fan switch in hall) 14 gauge wire on 20A circuit, No sheathing in box. Living wall only ok to cover
|
ELE17-04334
| Final | 4/23/2018 | 4/23/2018 | 4/23/2018 1:21:38 PM | P | PASS |
|
|
Roof top unit is in place. Phone #: ###-#### Inspection requested via web by Bryan Atkins final ok
|
ELE18-01503
| Rough-In Permanent Service | 4/23/2018 | 4/23/2018 | 4/23/2018 1:21:20 PM | P | CANC |
|
|
Douglas Phone #: ###-####
|
ELE18-01502
| Temporary Service | 4/23/2018 | 4/23/2018 | 4/23/2018 1:21:10 PM | P | PASS |
|
|
Temp service. t/s o/h n ok
|
ELE18-01533
| Electrical Rough-In | 4/23/2018 | 4/23/2018 | 4/23/2018 1:07:49 PM | P | PASS |
|
|
Wall Cover. Danny is the contact Phone #: ###-#### Inspection requested via web by Buster Bowenn Center offices only walls only ok to cover
|
ELE17-04172
| Final | 4/23/2018 | 4/23/2018 | 4/23/2018 10:26:27 AM | A | PASS |
|
|
Please give me half an hour notice before inspection to insure access. Thank you Shaun ###-#### Phone #: ###-#### Inspection requested via web by Shaun Kirkman Final ok
|
ELE18-00299
| Electrical Rough-In | 4/23/2018 | 4/23/2018 | 4/23/2018 9:50:10 AM | P | CANC |
|
|
THIS IS FOR THE WARM FLOOR IN THE MASTER BATHROOM Phone #: ###-#### >> Inspection requested via web by Bob Glenn Inspection cancelled from web by: Bob Glenn
|
ELE18-01526
| Rough-In Permanent Service | 4/22/2018 | 4/23/2018 | 4/23/2018 9:41:56 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Neal Rumsey rough in ok p/s u/g n ok
|
ELE18-00300
| Final | 4/20/2018 | 4/23/2018 | 4/23/2018 9:16:47 AM | A | PASS |
|
|
code 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn final ok
|