ELE02-00997
| Temporary Service | 4/23/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | A | PASS |
|
|
###-#### ron
T/S U/G Ok 4/24/2002 12:31:56 PM
|
ELE02-01072
| Rough-In Permanent Service | 4/23/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 04/23/2002 at 09:00:06. Contact: ###-####.I looked at all of the walls that were for the shell and core and I looked at the service also.
P/S U/G N Ok 4/24/2002 10:52:28 AM
|
ELE02-01071
| Rough-In Permanent Service | 4/23/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 04/23/2002 at 09:01:26. Contact: ###-####. I inspected the sofit and walls for the shell and core and the service
P/S U/G N Ok 4/24/2002 10:54:24 AM
|
ELE02-01186
| Electrical Rough-In | 4/23/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | A | FAIL |
|
|
dennis ###-#### r/i
Called Dennis Job requires a total rewire $45 reinspection fee 4/24/2002 11:46:28 AM
|
ELE02-01179
| Final | 4/23/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | P | FAIL |
|
|
Micheal ###-#### call first to meet
Grounding electrode and disconnect are required at this building also inuse covers on outside receps and protection of romex 4/24/2002 5:13:12 PM
|
ELE02-00401
| Electrical Rough-In | 4/24/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 04/24/2002 at 10:42:32. Contact: ###-####.
|
ELE02-00541
| Electrical Rough-In | 4/24/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 04/24/2002 at 10:43:44. Contact: ###-####.
|
ELE02-00402
| Electrical Rough-In | 4/24/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 04/24/2002 at 10:44:35. Contact: ###-####.
|
ELE02-00403
| Electrical Rough-In | 4/24/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 04/24/2002 at 10:46:03. Contact: ###-####.
|
ELE02-00404
| Electrical Rough-In | 4/24/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 04/24/2002 at 10:46:49. Contact: ###-####.
|
ELE02-00405
| Electrical Rough-In | 4/24/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 04/24/2002 at 10:47:34. Contact: ###-####.
|
ELE02-00407
| Electrical Rough-In | 4/24/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 04/24/2002 at 10:48:27. Contact: ###-####.
|
ELE02-00406
| Electrical Rough-In | 4/24/2002 | 4/24/2002 | 4/24/2002 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 04/24/2002 at 10:49:17. Contact: ###-####.
|