Inspections for the day of: Thursday, April 24, 2008.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-03939 Electrical Rough-In4/24/20084/24/20084/24/2008 4:11:30 PMPCANC
Ceiling cover inspection. Phone #: ###-#### Internet Inspection Request from: Kathy Smith done, duplicate request
ELE08-00305 Rough-In Permanent Service4/24/20084/24/20084/24/2008 3:38:26 PMPPASS
Scheduled by a contractor via Hello! on 4/24/2008 at 9:19:07 AM. Contact: ###-####. looked at secondary of transformer, met contractor, they are heating up transformer now , ri ok, p/s ok as per request from contractor. p/s passed on 4-17-08
ELE08-01035 Final4/24/20084/24/20084/24/2008 2:58:09 PMPPASS
ok to final
ELE07-03939 Electrical Rough-In4/24/20084/24/20084/24/2008 2:07:52 PMPPASS
Ceiling cover inspection. Phone #: ###-#### Internet Inspection Request from: Kathy Smith met contractor, ok to cover ceilings
ELE08-01035 Electrical Rough-In4/23/20084/24/20084/24/2008 1:06:42 PMPPASS
outlet for oxygen machine is ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten ric ok
ELE08-01005 Electrical Rough-In4/23/20084/24/20084/24/2008 10:58:58 AMAPASS
dallas Phone #: ###-#### u/g ok to cover transformer to gear , talked about making service up to code
ELE08-01036 Conference4/23/20084/24/20084/24/2008 9:38:49 AMADONE
theron Phone #: ###-#### met owner,reviewd basic wiring for 3 circuit addition into fish tank room, told him he should read a basic wiring book, when to call for ri
ELE08-00641 Final4/23/20084/24/20084/24/2008 9:00:47 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Mick Williams called, left correction notice, BCC shall install outside fixtures, shall meet 2005 NEC requirements, NEC 210.52 shall meet outlet spacing in kitchen, 210.8(A)(6) kitchen receptacles shall be gfci protected, 334.15(B) nm cable shall be protected for microwave, 110.3(B) equipment shall be installed per listing- reverse polarity by patio door, 406.5 shall install receptacle faceplate for disposal,408.4 circuit directory shall be clear, concise and explanatory for each circuit, 422.31(B) shall install disconnect for hot water heater, Note a/c shall be installed or circuiting abandoned
ELE08-00583 Final4/23/20084/24/20084/24/2008 8:08:05 AMANH
nick Phone #: ###-#### called contractor, will call when open, key did not work