Inspections for the day of: Tuesday, April 25, 2000.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBill VanDegrift
TitlePLM-INSPECTOR
Phone #794-9372
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM00-00937 Groundwork4/24/20004/25/20004/25/2000 12:00:00 AMAPART
g/w coit ###-#### next 4 sw ok 4/25/00 9:33:03 AM
PLM00-01230 Sprinkler (Final)4/24/20004/25/20004/25/2000 12:00:00 AMAFAIL
###-#### unions required, test required, no tee allowed upstream of dcva 4/25/00 9:32:38 AM left notice no answer to call 4/25/00 9:36:40 AM
PLM00-01171 Water and/or Sewer4/25/20004/25/20004/25/2000 12:00:00 AMAPASS
Added by Inspector: 330 On 4/25/00 map
PLM00-01184 Water and/or Sewer4/25/20004/25/20004/25/2000 12:00:00 AMAPASS
Added by Inspector: 330 On 4/25/00 map
PLM00-01218 Water and/or Sewer4/25/20004/25/20004/25/2000 12:00:00 AMAPASS
Added by Inspector: 330 On 4/25/00 map
PLM99-04209 Plumbing Rough-in4/25/20004/25/20004/25/2000 12:00:00 AMPPASS
Added by Inspector: 330 On 4/25/00 r/i ok
PLM99-03659 Other4/25/20004/25/20004/25/2000 12:00:00 AMPPASS
Added by Inspector: 330 On 4/25/00 water heater conference ok t&p drain with in 2' of garage floor
PLM00-01169 Plumbing Rough-in4/25/20004/25/20004/25/2000 12:00:00 AMPPASS
Added by Inspector: 330 On 4/25/00 addition only
PLM99-03863 Plumbing Rough-in4/25/20004/25/20004/25/2000 12:00:00 AMPPASS
raul ###-#### 2nd half
PLM99-03865 Plumbing Rough-in4/25/20004/25/20004/25/2000 12:00:00 AMPFAIL
raul ###-#### piping incomplete 4/25/00 2:43:24 PM
PLM00-01236 Water and/or Sewer4/25/20004/25/20004/25/2000 12:00:00 AMPFAIL
###-#### piping incomplete 4/25/00 3:15:21 PM
PLM00-00752 Plumbing Rough-in4/25/20004/25/20004/25/2000 12:00:00 AMPFAIL
Gary Tracy ###-#### wv tet failed, pex less than 12" from recessed light, secure wh stubouts, many bad joints in w&v system, vents backgraded, main vtr trapped, vent below trap wier, ks waste backgraded, hang pvc every 4' 4/25/00 5:02:36 PM
PLM00-01240 Plumbing Rough-in4/25/20004/25/20004/25/2000 12:00:00 AMPPASS
after 1:30 ###-####
PLM00-00783 Water and/or Sewer4/25/20004/25/20004/25/2000 12:00:00 AMPPART
tech plum --###-#### water & swr tech is takig outside portion of this project part sewer ok from ldg to withi 20 foot of tiein 4/25/00 3:49:07 PM
PLM00-01246 Sprinkler (Final)4/25/20004/25/20004/25/2000 12:00:00 AMPFAIL
after 3pm ###-#### Craig test dcva, no tees allowed upstream of dcva 4/25/00 3:29:47 PM
PLM00-00937 Groundwork4/25/20004/25/20004/25/2000 12:00:00 AMPPART
Scheduled by Inspector: 330 On 4/25/00 3 more sw ok 4/25/00 11:14:54 AM