Inspections for the day of: Thursday, April 25, 2002.
Number of inspections: 7
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD01-02848 BLD-Framing/Rough-in3/13/20024/25/20024/25/2002 12:00:00 AMAFAIL
4/25/2002 1:18:06 PM gyp on area septration wa;ll at each end needs lap of 24 horrizontal. 4/25/2002 1:46:20 PM
BLD01-03161 BLD-Final4/24/20024/25/20024/25/2002 12:00:00 AMAPART
MIKE ###-#### bld ok pending fire sign off. 4/25/2002 5:00:23 PM
BLD02-00763 BLD-Final4/24/20024/25/20024/25/2002 12:00:00 AMAPASS
###-####
BLD01-02610 BLD-Framing/Rough-in4/24/20024/25/20024/25/2002 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 04/24/2002 at 18:16:05. Contact: ###-####.
BLD01-01272 BLD-Final4/25/20024/25/20024/25/2002 12:00:00 AMPPART
1. HAND RAILS - Stairways serving a private dwelling shall have at least one handrail except that a handrail is not required for stairways having less than four (4) risers. The top of handrails shall be placed not less than 34 inches or more than 38 inches above the nosing of treads. Handrails shall be continuous the full length of the stairs. Ends shall be returned or shall have rounded terminations or bends. The handgrip portion of handrails shall not be less than 1-1/4 inches nor more than 2 inches in cross-sectional dimension or the shape shall provide an equivalent gripping surface. The handgrip portion of handrails shall have a smooth surface with no sharp corners. Handrails projecting from a wall shall have a space of not less than 1-1/2 inches between the wall and the handrail. (1997 UBC 1003.3.3.6)
BLD01-00967 BLD-Framing/Rough-in4/25/20024/25/20024/25/2002 12:00:00 AMPPART
fr tim ###-#### nail trusses to girder/ complet draft stop/ok to insulate walls only. 4/25/2002 4:17:48 PM
BLD01-03112 BLD-Framing/Rough-in4/25/20024/25/20024/25/2002 12:00:00 AMPPART
Scheduled by a contractor via Hello! on 04/25/2002 at 10:41:43. Contact: ###-####. c/n header over plm bearing studs/ naill sheer wall at plm panel void. ok to insulate bld. 4/25/2002 3:22:48 PM