ELE05-02003
| Electrical Rough-In | 4/25/2006 | 4/26/2006 | 4/26/2006 2:08:16 PM | A | PART |
|
|
Phone #: ###-#### Internet Inspection Request from: Marsha Smylie 3rd and 4th floors anop
|
ELE06-00182
| Electrical Rough-In | 4/26/2006 | 4/26/2006 | 4/26/2006 12:09:35 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 4/26/2006 at 9:37:30 AM. Contact: ###-####. corr. called excavator covered u/g from house to shop before inspection
|
ELE05-02257
| Final | 4/25/2006 | 4/26/2006 | 4/26/2006 11:31:51 AM | A | PASS |
|
|
raina; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok
|
ELE06-01414
| Electrical Rough-In | 4/24/2006 | 4/26/2006 | 4/26/2006 9:50:14 AM | A | FAIL |
|
|
###-####; Phone #: ###-#### Internet Inspection Request from: Rita corr met owner, 210.52(A) outlet spacing everywhere, 300.4 nail plates and 11/4", 210.12 afci for all circuits in bed rm, 334.24 radius of cables, 334.80 not more than 2 cables in holes unless you derate, note update permit for 3 rms and up to 20kw of elect heat, install all boxes outside lignts, 314.16 box fill
|
ELE06-00445
| Final | 4/26/2006 | 4/26/2006 | 4/26/2006 9:04:57 AM | A | PASS |
|
|
charlie Internet Inspection Request from: Melyne Davis ok
|
ELE06-00700
| Final | 4/25/2006 | 4/26/2006 | 4/26/2006 8:38:19 AM | A | NH |
|
|
Scheduled by a contractor via Hello! on 4/25/2006 at 10:43:35 AM. Contact: ###-####. Note: please call for code called no answer left message waited 5 min. no call back no access
|
ELE06-00125
| Permanent Service | 4/25/2006 | 4/26/2006 | 4/26/2006 8:04:29 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Marsha Smylie p/s u/g new ok
|
ELE06-01340
| Permanent Service | 4/25/2006 | 4/26/2006 | 4/26/2006 12:00:00 AM | P | CANC |
|
|
Number for Justin Metcalf; Phone #: ###-#### Internet Inspection Request from: Justin Metcalf
|