Inspections for the day of: Thursday, April 26, 2007.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-00046 Final4/26/20074/26/20074/26/2007 4:00:52 PMPFAIL
This inspection will be for a temporary occupancy only. Thank you Phone #: ###-#### Internet Inspection Request from: Laura Longshaw 210.8 com. kit all 15&20 amp 120V recepts shall have gfci protection
ELE07-01247 Rough-In Permanent Service4/26/20074/26/20074/26/2007 3:36:17 PMPPASS
contact gene ###-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson r/i ok 4 units p/s u/g new ok
ELE07-01425 Final4/26/20074/26/20074/26/2007 2:50:00 PMPFAIL
CONTACT: BRIAN WEIBYE Phone #: ###-#### Internet Inspection Request from: Deb Gooden shall install outside fixture for back exit 210.70
ELE06-01645 Final4/26/20074/26/20074/26/2007 2:48:59 PMPFAIL
brian - call 30 min prior; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called needs #8 equip grd manufactures instructions
ELE07-01042 Final4/26/20074/26/20074/26/2007 2:15:58 PMPPASS
DAVE BRADSHAW - HE WILL MEET @ JOB SITE Phone #: ###-#### Internet Inspection Request from: Randy Vail called left message needs minimum #8 copper bonding service equip secondary side of xformer
ELE07-00393 Final4/26/20074/26/20074/26/2007 1:38:14 PMPFAIL
Scheduled by a contractor via Hello! on 4/26/2007 at 10:34:28 AM. Contact: ###-####. corr. posted called 408.4 panel schedule shall be specific, 210.11(C)(3) remove outside and inside recepts from required 20 amp bath circuit
ELE07-00308 Final4/26/20074/26/20074/26/2007 1:26:04 PMPFAIL
Scheduled by a contractor via Hello! on 4/26/2007 at 10:33:22 AM. Contact: ###-####. corr called 314,3 shall remove metallic race from plastic box island
ELE07-01442 Rough-In Permanent Service4/26/20074/26/20074/26/2007 12:28:56 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe see added p/s, corr. fee due called 300.4 (A)(1) shall provide nail plates where required told contr the same thing in the AM today
ELE07-01442 Permanent Service4/26/20074/26/20074/26/2007 12:25:48 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Rowdy Monroe p/s u/g new ok
ELE07-01450 Rough-In Permanent Service4/26/20074/26/20074/26/2007 10:39:35 AMPPASS
Dan call before you arrive; Phone #: ###-#### Internet Inspection Request from: Victoria Beall p/s u/g new ok
ELE07-01481 Rough-In Permanent Service4/25/20074/26/20074/26/2007 10:00:36 AMACANC
robert; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
needs bld permit called
ELE07-01480 Rough-In Permanent Service4/25/20074/26/20074/26/2007 10:00:09 AMACANC
robert; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
needs bld permit called
ELE07-01482 Rough-In Permanent Service4/25/20074/26/20074/26/2007 9:59:40 AMACANC
robert; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
needs bld permit called
ELE07-01475 Electrical Rough-In4/25/20074/26/20074/26/2007 9:47:05 AMAFAIL
darin; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
corr. do not cover posted called300.4 nail plates 11/4" 334.23 protect romex at attic access, 312.5 conn for low volt cables, and staple, 334.30 & 314.17(C) staple romex within 8" of boxes, 314.20 outside boxes shall be flush with siding, BCC makeup all outside boxes
ELE07-01369 Temporary Service4/26/20074/26/20074/26/2007 9:03:54 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Tracy Robertson t/s u/g new ok
ELE07-01448 Rough-In Permanent Service4/26/20074/26/20074/26/2007 8:48:58 AMAPASS
Scheduled by a contractor via Hello! on 4/26/2007 at 5:20:45 AM. Contact: ###-####. r/i p/s u/g new ok
ELE05-04290 DOC - Permit Expired4/26/20074/26/20074/26/2007 7:33:43 AMAPASS
ELE07-00162 ELE-Aging Inspection4/26/20074/26/20074/26/2007 7:31:18 AM PART
talked with contractor WSUC