ELE16-01318
| Electrical Rough-In | 4/25/2016 | 4/26/2016 | 4/26/2016 2:47:02 PM | P | PASS |
|
|
Underground/bonding Phone #: ###-#### Inspection requested via web by Lars Johnson underground and equipentential bond ok cover
|
ELE16-00837
| Electrical Rough-In | 4/25/2016 | 4/26/2016 | 4/26/2016 2:17:03 PM | P | FAIL |
|
|
I am requesting a late inspection due to limited access to the property. We will not be able to access the property until after 4 p.m. please call with any questions Phone #: ###-#### Inspection requested via web by Cortney Hopper 300.4 (d) cables slong flat framing member shall be held 1 1/4" from surface of a member 334.30 Type NM cable shall be supported every 4 1/2' 210.4 (b) each multi wire branch circuit shall have means to discconect all ungrounded cunductors
|
ELE15-03335
| Electrical Rough-In | 4/26/2016 | 4/26/2016 | 4/26/2016 1:34:07 PM | P | FAIL |
|
|
Contact: Jason Noble Phone #: ###-#### Inspection requested via web by Deb Gooden 210.52 (4)(b)Receptacles in a dining room shall be on 20 amp small appliance circuit
|
ELE13-02018
| ELE-Aging Inspection | 4/26/2016 | 4/26/2016 | 4/26/2016 12:35:38 PM | | PASS |
|
|
too busy
|
ELE16-00431
| Electrical Rough-In | 4/25/2016 | 4/26/2016 | 4/26/2016 12:05:22 PM | A | CANC |
|
|
Re inspection of Building O Phone #: ###-#### Inspection requested via web by Bob Stephens
|
ELE16-00431
| Rough-In Permanent Service | 4/26/2016 | 4/26/2016 | 4/26/2016 12:04:03 PM | P | PASS |
|
|
Re inspection of Building O Phone #: ###-#### Inspection requested via web by Bob Stephens building O ok cover p/s u/g n ok
|
ELE15-03858
| Electrical Rough-In | 4/25/2016 | 4/26/2016 | 4/26/2016 11:15:14 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Kerri Hamilton wrong permit called in
|
ELE15-02531
| Final | 4/25/2016 | 4/26/2016 | 4/26/2016 10:47:51 AM | A | FAIL |
|
|
Call with any question or access issues. I will not be on site. Phone #: ###-#### Inspection requested via web by Garrett Collins 210.70 (a)(1) at least one walls switched controlled lighting outlet shall be installed 422.31 fixed appliances shall have means of lock out 410.16(2)(2) surface mounted flour fixtures shall maintain 6' from storage spaces
|
ELE16-00542
| Final | 4/25/2016 | 4/26/2016 | 4/26/2016 10:10:43 AM | A | PASS |
|
|
Home will be ready for final inspection, doors will be open at 8:00 AM. Call me with any questions. Phone #: ###-#### Inspection requested via web by Kurt Carlson final ok
|
ELE10-01532
| Final | 4/25/2016 | 4/26/2016 | 4/26/2016 9:44:38 AM | A | FAIL |
|
|
Dean// please call ahead Phone #: ###-#### to many items to list its on correction notice
|
ELE16-01015
| Electrical Rough-In | 4/25/2016 | 4/26/2016 | 4/26/2016 8:57:28 AM | A | PASS |
|
|
Ceiling inspection. Shane is the contact his cell no. is ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates cieling only ok cover
|
ELE16-01257
| Electrical Rough-In | 4/26/2016 | 4/26/2016 | 4/26/2016 12:00:00 AM | P | CANC |
|
|
Phone #: ###-#### >> Inspection requested via web by Jarod Murray
|