Inspections for the day of: Tuesday, April 26, 2016.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Story
TitleELE-INSPECTOR
Phone #985-3493
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE16-01318 Electrical Rough-In4/25/20164/26/20164/26/2016 2:47:02 PMPPASS
Underground/bonding Phone #: ###-#### Inspection requested via web by Lars Johnson underground and equipentential bond ok cover
ELE16-00837 Electrical Rough-In4/25/20164/26/20164/26/2016 2:17:03 PMPFAIL
I am requesting a late inspection due to limited access to the property. We will not be able to access the property until after 4 p.m. please call with any questions Phone #: ###-#### Inspection requested via web by Cortney Hopper 300.4 (d) cables slong flat framing member shall be held 1 1/4" from surface of a member 334.30 Type NM cable shall be supported every 4 1/2' 210.4 (b) each multi wire branch circuit shall have means to discconect all ungrounded cunductors
ELE15-03335 Electrical Rough-In4/26/20164/26/20164/26/2016 1:34:07 PMPFAIL
Contact: Jason Noble Phone #: ###-#### Inspection requested via web by Deb Gooden 210.52 (4)(b)Receptacles in a dining room shall be on 20 amp small appliance circuit
ELE13-02018 ELE-Aging Inspection4/26/20164/26/20164/26/2016 12:35:38 PM PASS
too busy
ELE16-00431 Electrical Rough-In4/25/20164/26/20164/26/2016 12:05:22 PMACANC
Re inspection of Building O Phone #: ###-#### Inspection requested via web by Bob Stephens
ELE16-00431 Rough-In Permanent Service4/26/20164/26/20164/26/2016 12:04:03 PMPPASS
Re inspection of Building O Phone #: ###-#### Inspection requested via web by Bob Stephens building O ok cover p/s u/g n ok
ELE15-03858 Electrical Rough-In4/25/20164/26/20164/26/2016 11:15:14 AMACANC
Phone #: ###-#### Inspection requested via web by Kerri Hamilton wrong permit called in
ELE15-02531 Final4/25/20164/26/20164/26/2016 10:47:51 AMAFAIL
Call with any question or access issues. I will not be on site.
Phone #: ###-#### Inspection requested via web by Garrett Collins 210.70 (a)(1) at least one walls switched controlled lighting outlet shall be installed 422.31 fixed appliances shall have means of lock out 410.16(2)(2) surface mounted flour fixtures shall maintain 6' from storage spaces
ELE16-00542 Final4/25/20164/26/20164/26/2016 10:10:43 AMAPASS
Home will be ready for final inspection, doors will be open at 8:00 AM. Call me with any questions. Phone #: ###-#### Inspection requested via web by Kurt Carlson final ok
ELE10-01532 Final4/25/20164/26/20164/26/2016 9:44:38 AMAFAIL
Dean// please call ahead Phone #: ###-#### to many items to list its on correction notice
ELE16-01015 Electrical Rough-In4/25/20164/26/20164/26/2016 8:57:28 AMAPASS
Ceiling inspection. Shane is the contact his cell no. is ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates cieling only ok cover
ELE16-01257 Electrical Rough-In4/26/20164/26/20164/26/2016 12:00:00 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Jarod Murray