ELE06-01414
| Electrical Rough-In | 4/27/2006 | 4/27/2006 | 4/27/2006 4:41:03 PM | P | PASS |
|
|
corr made, ric ok
|
ELE06-00979
| Final | 4/27/2006 | 4/27/2006 | 4/27/2006 3:45:48 PM | P | NH |
|
|
wrhels ele ; Phone #: ###-#### Internet Inspection Request from: Marsha called contr, he will recall
|
ELE06-01374
| Electrical Rough-In | 4/27/2006 | 4/27/2006 | 4/27/2006 2:57:45 PM | P | PASS |
|
|
cathy ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie reviewed grounding for piping, no cord for fixed equipment, mc strapping, emt strapping on exposed work ,adding gfci over offices for air heater, ok to cover sheet-rock part in offices, equip has etl labels, ric ok, will do service later
|
ELE06-01462
| Rough-In Permanent Service | 4/27/2006 | 4/27/2006 | 4/27/2006 2:39:58 PM | P | FAIL |
|
|
john- cell ###-####--call 1st before insp for access called contr, left corr notice, nec 300.4(A) & (D) edge of holes and nm cable shall be 1 1/4" from edge of framing members, 250.86 metal box in garage ceiling shall be grounded, 210.52(A) shall add recpt to wall in lr , BCC all make-up shall be done,smokes and a/c
|
ELE06-01062
| Final | 4/27/2006 | 4/27/2006 | 4/27/2006 1:36:05 PM | P | PASS |
|
|
Chris; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok to final, signed card for occupancy
|
ELE06-00925
| Electrical Rough-In | 4/26/2006 | 4/27/2006 | 4/27/2006 10:32:45 AM | A | CANC |
|
|
tolly - new addition; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, wrong type permit
|
ELE06-00925
| Permanent Service | 4/26/2006 | 4/27/2006 | 4/27/2006 10:26:12 AM | A | CANC |
|
|
tolly; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contr, wrong type permit
|
ELE06-01449
| Temporary Service | 4/26/2006 | 4/27/2006 | 4/27/2006 9:56:40 AM | A | PASS |
|
|
###-#### - mike called contr, left survey, nec 11o.12(C) there shall be no broken parts,50a recpt, 250.24(A) gec shall be connected togrounded conductor term, t/s u/g n ok
|
ELE06-00865
| Final | 4/26/2006 | 4/27/2006 | 4/27/2006 9:27:33 AM | A | PASS |
|
|
Trent; Phone #: ###-#### Internet Inspection Request from: Rita DeYoung ok to final, signed struct card
|
ELE06-00115
| Final | 4/26/2006 | 4/27/2006 | 4/27/2006 8:53:43 AM | A | PASS |
|
|
code=2241; Phone #: ###-#### Internet Inspection Request from: William Zerfas called contr to put cover on gec access point, irrigation pump later under new permit. ok to final
|
ELE06-00416
| Permanent Service | 4/26/2006 | 4/27/2006 | 4/27/2006 5:34:36 AM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: todd hall p/s u/g rec ok, told elect and contractor about nec 230.7, no feeder wire in service wireway
|