Inspections for the day of: Friday, April 27, 2007.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-00282 ELE-Aging Inspection4/27/20074/27/20074/27/2007 4:45:33 PM DONE
see final
ELE07-00282 Final4/27/20074/27/20074/27/2007 4:44:44 PMAPASS
looked at sign, ok to final
ELE07-01473 Electrical Rough-In4/27/20074/27/20074/27/2007 4:43:22 PMPFAIL
chris - re-inspection ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called contr, corrections not all made
ELE06-04055 Electrical Rough-In4/27/20074/27/20074/27/2007 3:57:08 PMPPASS
jerod Note: potting compound; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles potting ok
ELE07-01426 Final4/26/20074/27/20074/27/2007 3:04:11 PMPPASS
re inspection for sign wiring, any questions call George @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose called contr to add label in panel for signs, corrections made, ok to final
ELE06-03919 Final4/25/20074/27/20074/27/2007 2:17:03 PMPCANC
Daniel or Travis will have the key from the City of Boise for opening the gate into the control panel. Thanks Phone #: ###-#### Internet Inspection Request from: Daniel Gamboa see conference
ELE06-03919 Conference4/27/20074/27/20074/27/2007 2:16:39 PMPDONE
Daniel or Travis will have the key from the City of Boise for opening the gate into the control panel. Thanks Phone #: ###-#### Internet Inspection Request from: Daniel Gamboa met contr, too many violations. talked about voltage for system, grounding, listing elect equipment, service overcurrent protection, plugging openings, he will fix and request inspection when ready.
ELE07-01506 Rough-In Permanent Service4/26/20074/27/20074/27/2007 1:25:22 PMPCANC
john ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith see p/s and ri
ELE07-01506 Electrical Rough-In4/27/20074/27/20074/27/2007 1:24:10 PMPFAIL
john ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called left message, left corr notice, nec 300.5 direct burial conductors shall be 18" deep, 210.52 (A) (2) shall install recpt in kitchen 2' wall, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 334.30 shall not staple nm cable on edge
ELE07-01506 Permanent Service4/27/20074/27/20074/27/2007 1:20:59 PMPPASS
john ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith p/s o/h n ok
ELE07-01374 Temporary Service4/27/20074/27/20074/27/2007 12:50:52 PMPPASS
neil; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr made, t/s u/g n ok
ELE07-01114 Conference4/27/20074/27/20074/27/2007 12:17:59 PMPCANC
Greg- trench inspection for pool; Phone #: ###-#### Internet Inspection Request from: Darla Downs wrong type inspect, see ri
ELE07-01114 Electrical Rough-In4/27/20074/27/20074/27/2007 12:16:18 PMPPASS
Greg- trench inspection for pool; Phone #: ###-#### Internet Inspection Request from: Darla Downs ok to cover u/g pool equip to pool
ELE07-00997 Final4/27/20074/27/20074/27/2007 10:22:14 AMAPASS
ok to final
ELE07-01505 Electrical Rough-In4/26/20074/27/20074/27/2007 10:07:15 AMAPASS
Please contact Jim @###-#### for access Phone #: ###-#### Internet Inspection Request from: Joe Thomas ric ok
ELE07-01500 Final4/26/20074/27/20074/27/2007 9:26:07 AMAPASS
MITCH; Phone #: 2###-#### Internet Inspection Request from: Cathy Chiles p/s o/h rec ok, ok to final- see p/s
ELE07-01500 Permanent Service4/27/20074/27/20074/27/2007 9:24:59 AMAPASS
MITCH; Phone #: 2###-#### Internet Inspection Request from: Cathy Chiles p/s o/h rec ok
ELE07-01498 Rough-In Permanent Service4/26/20074/27/20074/27/2007 9:11:07 AMACANC
Spencer; Phone #: ###-#### Internet Inspection Request from: Victoria Beall see p/s for time and notes
ELE07-01498 Permanent Service4/27/20074/27/20074/27/2007 9:10:18 AMAFAIL
Spencer; Phone #: ###-#### Internet Inspection Request from: Victoria Beall met contr, told patio roof to close to service, will remove and recall, left corr notice, nec 230.24(A) service drop conductors shall be min 8' over roof
ELE07-00876 Final4/26/20074/27/20074/27/2007 8:34:01 AMAPASS
CONTACT: SHANE KORTE Phone #: ###-#### Internet Inspection Request from: Deb Gooden met elect, looked at re-model and service, ok to final
ELE07-01502 Temporary Service4/26/20074/27/20074/27/2007 8:00:59 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Dan Surerus t/s u/g n ok
ELE07-01460 Temporary Service4/26/20074/27/20074/26/2007 6:07:23 PMPCANC
Pls. call Dan at ###-#### with questions on inspection. Phone #: ###-#### Internet Inspection Request from: Raj Sandou Inspection cancelled from web by: Raj Sandou