ELE07-00282
| ELE-Aging Inspection | 4/27/2007 | 4/27/2007 | 4/27/2007 4:45:33 PM | | DONE |
|
|
see final
|
ELE07-00282
| Final | 4/27/2007 | 4/27/2007 | 4/27/2007 4:44:44 PM | A | PASS |
|
|
looked at sign, ok to final
|
ELE07-01473
| Electrical Rough-In | 4/27/2007 | 4/27/2007 | 4/27/2007 4:43:22 PM | P | FAIL |
|
|
chris - re-inspection ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called contr, corrections not all made
|
ELE06-04055
| Electrical Rough-In | 4/27/2007 | 4/27/2007 | 4/27/2007 3:57:08 PM | P | PASS |
|
|
jerod Note: potting compound; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles potting ok
|
ELE07-01426
| Final | 4/26/2007 | 4/27/2007 | 4/27/2007 3:04:11 PM | P | PASS |
|
|
re inspection for sign wiring, any questions call George @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose called contr to add label in panel for signs, corrections made, ok to final
|
ELE06-03919
| Final | 4/25/2007 | 4/27/2007 | 4/27/2007 2:17:03 PM | P | CANC |
|
|
Daniel or Travis will have the key from the City of Boise for opening the gate into the control panel. Thanks Phone #: ###-#### Internet Inspection Request from: Daniel Gamboa see conference
|
ELE06-03919
| Conference | 4/27/2007 | 4/27/2007 | 4/27/2007 2:16:39 PM | P | DONE |
|
|
Daniel or Travis will have the key from the City of Boise for opening the gate into the control panel. Thanks Phone #: ###-#### Internet Inspection Request from: Daniel Gamboa met contr, too many violations. talked about voltage for system, grounding, listing elect equipment, service overcurrent protection, plugging openings, he will fix and request inspection when ready.
|
ELE07-01506
| Rough-In Permanent Service | 4/26/2007 | 4/27/2007 | 4/27/2007 1:25:22 PM | P | CANC |
|
|
john ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith see p/s and ri
|
ELE07-01506
| Electrical Rough-In | 4/27/2007 | 4/27/2007 | 4/27/2007 1:24:10 PM | P | FAIL |
|
|
john ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called left message, left corr notice, nec 300.5 direct burial conductors shall be 18" deep, 210.52 (A) (2) shall install recpt in kitchen 2' wall, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 334.30 shall not staple nm cable on edge
|
ELE07-01506
| Permanent Service | 4/27/2007 | 4/27/2007 | 4/27/2007 1:20:59 PM | P | PASS |
|
|
john ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith p/s o/h n ok
|
ELE07-01374
| Temporary Service | 4/27/2007 | 4/27/2007 | 4/27/2007 12:50:52 PM | P | PASS |
|
|
neil; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr made, t/s u/g n ok
|
ELE07-01114
| Conference | 4/27/2007 | 4/27/2007 | 4/27/2007 12:17:59 PM | P | CANC |
|
|
Greg- trench inspection for pool; Phone #: ###-#### Internet Inspection Request from: Darla Downs wrong type inspect, see ri
|
ELE07-01114
| Electrical Rough-In | 4/27/2007 | 4/27/2007 | 4/27/2007 12:16:18 PM | P | PASS |
|
|
Greg- trench inspection for pool; Phone #: ###-#### Internet Inspection Request from: Darla Downs ok to cover u/g pool equip to pool
|
ELE07-00997
| Final | 4/27/2007 | 4/27/2007 | 4/27/2007 10:22:14 AM | A | PASS |
|
|
ok to final
|
ELE07-01505
| Electrical Rough-In | 4/26/2007 | 4/27/2007 | 4/27/2007 10:07:15 AM | A | PASS |
|
|
Please contact Jim @###-#### for access Phone #: ###-#### Internet Inspection Request from: Joe Thomas ric ok
|
ELE07-01500
| Final | 4/26/2007 | 4/27/2007 | 4/27/2007 9:26:07 AM | A | PASS |
|
|
MITCH; Phone #: 2###-#### Internet Inspection Request from: Cathy Chiles p/s o/h rec ok, ok to final- see p/s
|
ELE07-01500
| Permanent Service | 4/27/2007 | 4/27/2007 | 4/27/2007 9:24:59 AM | A | PASS |
|
|
MITCH; Phone #: 2###-#### Internet Inspection Request from: Cathy Chiles p/s o/h rec ok
|
ELE07-01498
| Rough-In Permanent Service | 4/26/2007 | 4/27/2007 | 4/27/2007 9:11:07 AM | A | CANC |
|
|
Spencer; Phone #: ###-#### Internet Inspection Request from: Victoria Beall see p/s for time and notes
|
ELE07-01498
| Permanent Service | 4/27/2007 | 4/27/2007 | 4/27/2007 9:10:18 AM | A | FAIL |
|
|
Spencer; Phone #: ###-#### Internet Inspection Request from: Victoria Beall met contr, told patio roof to close to service, will remove and recall, left corr notice, nec 230.24(A) service drop conductors shall be min 8' over roof
|
ELE07-00876
| Final | 4/26/2007 | 4/27/2007 | 4/27/2007 8:34:01 AM | A | PASS |
|
|
CONTACT: SHANE KORTE Phone #: ###-#### Internet Inspection Request from: Deb Gooden met elect, looked at re-model and service, ok to final
|
ELE07-01502
| Temporary Service | 4/26/2007 | 4/27/2007 | 4/27/2007 8:00:59 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Surerus t/s u/g n ok
|
ELE07-01460
| Temporary Service | 4/26/2007 | 4/27/2007 | 4/26/2007 6:07:23 PM | P | CANC |
|
|
Pls. call Dan at ###-#### with questions on inspection. Phone #: ###-#### Internet Inspection Request from: Raj Sandou Inspection cancelled from web by: Raj Sandou
|