Inspections for the day of: Monday, April 27, 2015.
Number of inspections: 3
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD14-03474 BLD-Framing/Rough-in4/24/20154/27/20154/27/2015 12:04:44 PMAFAIL
Josh Phone #: ###-####. Nail off all simpson hangars, Nail T22 girder trus on opposite face and provide the additional cluster nailing as per truss engineering, seal all penetrations in OSB on open web floor joist for draft stop, Install all MST 48 floor to floor straps on exterior as shown on sheet A4, install the simpson DTT2 with 1/2" diameter all thread in 2 places at deck to interior floor joist with blocking for lateral. Correction notice posted. ok to insulate.
BLD15-01298 BLD-Framing/Rough-in4/27/20154/27/20154/27/2015 11:51:34 AMAPASS
Please make inspection after 10:00am to ensure access to project.

Thanks,
Perry Phone #: ###-#### Inspection requested via web by Perry Evans
BLD15-00982 BLD-Framing/Rough-in4/27/20154/27/20154/27/2015 10:10:49 AMAPART
Mark Phone #: ###-####. Interior steel stud walls. Needs to provide all approved drawings.