ELE17-01220
| Electrical Rough-In | 4/26/2017 | 4/27/2017 | 4/27/2017 1:59:35 PM | P | PASS |
|
|
no service inspection at this time Phone #: ###-#### Inspection requested via web by Emmet Bushman Service located on east side of garage and subfeeds house. 250.32 buildings fed by feeders or branch circuits shall have a grounding electrode system installed. Unable to locate a concrete encased electrode at house, ground rods must be installed when energized. Feeders not in at time of inspection and conduit needs relocated. Rough in ok cover
|
ELE17-01220
| Permanent Service | 4/27/2017 | 4/27/2017 | 4/27/2017 1:42:34 PM | P | PASS |
|
|
no service inspection at this time Phone #: ###-#### Inspection requested via web by Emmet Bushman Service installed at time of inspection however underground must be relocated. p/s u/g n ok
|
ELE17-01211
| Temporary Service | 4/26/2017 | 4/27/2017 | 4/27/2017 9:42:18 AM | A | PASS |
|
|
Any issues plz let me know, thx, TW Phone #: ###-#### Inspection requested via web by Stephen Kren t/s u/g n ok
|
ELE17-01180
| Rough-In Permanent Service | 4/26/2017 | 4/27/2017 | 4/27/2017 9:24:12 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn Rough in ok cover p/s u/g n ok
|
ELE17-01202
| Temporary Service | 4/26/2017 | 4/27/2017 | 4/27/2017 8:48:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Rowdy Monroe t/s u/g n ok
|
ELE17-01165
| Rough-In Permanent Service | 4/26/2017 | 4/27/2017 | 4/26/2017 2:18:23 PM | A | PASS |
|
|
Alan Phone #: ###-#### Batting insulation removed Thank You. Rough in ok cover p/s u/g n ok
|