Inspections for the day of: Monday, April 28, 2014.
Number of inspections: 7
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-00661 ELE-Aging Inspection4/28/20144/28/20144/28/2014 4:08:54 PM DONE
Drove by posted correction
ELE14-00672 Final4/28/20144/28/20144/28/2014 3:28:29 PMPPASS
Rock

If you go to the front desk they can get you into the exercise room and the ada room #119 I think is the number. The newly remodled bath room. Thanks Mike Phone #: ###-#### >> Inspection requested via web by Mike Cole Final ok
ELE14-01044 Final4/28/20144/28/20144/28/2014 2:45:39 PMPFAIL
Garage wired. I will leave the back door open. Phone #: ###-#### >> Inspection requested via web by Greg Idsinga 406.11-In all areas specified in 210.52, all 120 volt 15 and 20 amp receptical outlets shall be listed tamper resistant recepticals. Garages included
ELE14-01050 Permanent Service4/28/20144/28/20144/28/2014 2:18:43 PMPPART
The new service is on the East side of the garage. There is also a new panel on the Sout side of the house by the hot tub. 250.32- grounding electrode system shall be established at rmote building (house). Main service rough in ok. p/s u/g n ok

Please call when you are on the way so that the owner can be advised that you will be on site. Phone #: ###-#### >> Inspection requested via web by Spencer McLean
ELE14-00636 Electrical Rough-In4/28/20144/28/20144/28/2014 1:22:10 PMPPASS
Trenching/conduit//Please call ahead for access- casey Phone #: ###-#### Tamper resistant recepticals required and access for concrete encased electrode. Rough in ok cover
ELE14-01046 Rough-In Permanent Service4/28/20144/28/20144/28/2014 12:29:49 PMPPASS
Phone #: ###-#### >> Inspection requested via web by TOM BICANDI Rough in ok cover p/s u/g n ok
ELE14-01024 Conference4/24/20144/28/20144/28/2014 9:55:49 AMADONE
Robert ###-#### Discussed GFCI protection of kitchen receptical outlets, AFCI protection of all bedroom outlets, establish ground at detached garage, abrasion protection at junction boxes in garage. All wires fished in walls. Basement ceiling rough in ok cover