Inspections for the day of: Thursday, April 28, 2016.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorChad Schwendiman
TitleMEC-INSPECTOR
Phone #780-9549
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC16-01067 Final4/28/20164/28/20164/28/2016 4:19:03 PMPPART
If you have any questions please contact Karl at ###-#### Thank you have a great day:) Phone #: ###-#### Inspection requested via web by Karl Hestekin - okay to cover grid celings. Need air balance report for hoods, need permenant roof ladder in place
MEC16-01191 Final4/25/20164/28/20164/28/2016 3:53:19 PMPPASS
Richard Phone #: ###-#### Inspection requested via web by Michele Atwood
MEC16-01745 Final4/28/20164/28/20164/28/2016 3:33:30 PMPNH
Contact Alan for access: ###-#### Phone #: ###-#### Inspection requested via web by Frank - left a notice
MEC15-04785 Mec-Aging Inspection4/28/20164/28/20164/28/2016 3:17:12 PM PASS
MEC15-04785 Final4/28/20164/28/20164/28/2016 3:16:49 PMPPASS
MEC15-04773 Mec-Aging Inspection4/28/20164/28/20164/28/2016 3:10:09 PM CANC
MEC16-01037 Final4/28/20164/28/20164/28/2016 2:55:21 PMPFAIL
For a Mini split AC Phone #: ###-#### Inspection requested via web by Dan McFate - need liquid tight electrical flex on a/c
MEC16-01767 Final4/28/20164/28/20164/28/2016 2:33:17 PMPPASS
Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC16-00908 Final4/28/20164/28/20164/28/2016 1:47:49 PMPPASS
Phone #: ###-#### Inspection requested via web by Dan Otero
MEC16-01655 Pressure Test4/28/20164/28/20164/28/2016 1:19:09 PMPPASS
if questions call Gary @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia Haumann - 20lb gas pass
MEC16-01745 Final4/28/20164/28/20164/28/2016 10:28:23 AMPCANC
Shaun: ###-#### Phone #: ###-#### >> Inspection requested via web by Frank Marturello Inspection cancelled from web by: Frank Marturello
MEC16-01768 Final4/27/20164/28/20164/28/2016 9:39:46 AMAPASS
Exhaust fan in bathroom. Someone will be on sight to allow access. Phone #: ###-#### Inspection requested via web by Rick Montgomery
MEC16-01618 Rough-in4/28/20164/28/20164/28/2016 9:23:25 AMAPASS
Corridors Inspection requested via web by william kerwin - okay to cover corridor ceilings
MEC16-01751 Pressure Test4/27/20164/28/20164/28/2016 8:54:15 AMAPASS
Main contact and plumber is Nic please call him prior to arrival or should you have any questions at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Maira Guzman - 20lb gas pass
MEC16-01655 Pressure Test4/27/20164/28/20164/28/2016 8:14:12 AMAFAIL
if questions call Gary @ ###-#### Phone #: ###-#### Inspection requested via web by Stacia - wrong gauge on the gas piping. need to test low pressure gas piping at 20lbs on a 30lb gauge