MEC20-01366
| Rough-in | 4/28/2020 | 4/28/2020 | 4/28/2020 4:03:03 PM | P | PART |
|
|
please call nic prior to arrival for access Phone #: ###-#### Inspection requested via web by Nicholas Paige - partial duct seal ok for insulation (marked prints)
|
MEC20-01122
| Final | 4/28/2020 | 4/28/2020 | 4/28/2020 3:15:22 PM | P | PASS |
|
|
###-#### Mike Priest with Renaissance Remodeling Phone #: ###-#### Inspection requested via web by Arielle Hendricks - final ok
|
MEC20-01651
| Final | 4/27/2020 | 4/28/2020 | 4/28/2020 3:07:51 PM | P | PASS |
|
|
Please call Brandan before going to the job site. Phone #: ###-#### Inspection requested via web by Dennis Fox - 5lb flue test ok - furnace only co ok
|
MEC20-01656
| Final | 4/28/2020 | 4/28/2020 | 4/28/2020 2:48:14 PM | P | PASS |
|
|
Repair not adding anything Phone #: ###-#### Inspection requested via web by Sean Hyten - final ok
|
MEC20-01656
| Pressure Test | 4/28/2020 | 4/28/2020 | 4/28/2020 2:48:02 PM | P | PASS |
|
|
Repair not adding anything Phone #: ###-#### Inspection requested via web by Sean Hyten - 20lb underground gas test ok for backfill
|
MEC20-01496
| Rough-in | 4/27/2020 | 4/28/2020 | 4/28/2020 2:33:46 PM | P | FAIL |
|
|
Please call the number provided when on the way. Phone #: ###-#### Inspection requested via web by Steve Bunch - fresh air termination cant go out roof - floor boots need sealed - duct work needs sealed - dryer vent needs backdraft and no screen
|
MEC20-01496
| Pressure Test | 4/27/2020 | 4/28/2020 | 4/28/2020 2:32:46 PM | P | PASS |
|
|
Please call the number provided when on the way. Phone #: ###-#### Inspection requested via web by Steve Bunch - 5lb flue test ok - 20lb gas test ok
|
MEC20-01604
| Pressure Test | 4/28/2020 | 4/28/2020 | 4/28/2020 2:32:02 PM | P | PASS |
|
|
INSTALLER JAMES ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt 3- 20lb underground gas pressure tests ok for backfill
|
MEC20-01568
| Final | 4/24/2020 | 4/28/2020 | 4/28/2020 1:39:17 PM | P | PASS |
|
|
Furnace in garage. Homeowner David Chase ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok
|
MEC20-00254
| Final | 4/28/2020 | 4/28/2020 | 4/28/2020 12:03:57 PM | P | FAIL |
|
|
Mechanical Gas Fireplace Final Inspection. Manual is in kitchen drawer left of stove top. Garage Code: 9000 Phone #: ###-#### Inspection requested via web by Dan Otero - gas valve needs to be accessible
|
MEC20-01606
| Final | 4/28/2020 | 4/28/2020 | 4/28/2020 12:02:43 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette - final ok
|
MEC20-01448
| Final | 4/28/2020 | 4/28/2020 | 4/28/2020 12:02:11 PM | P | PASS |
|
|
electrical permit has been pulled. Phone #: ###-#### Inspection requested via web by max sanders - final ok
|
MEC20-01640
| Final | 4/27/2020 | 4/28/2020 | 4/28/2020 10:46:15 AM | A | PASS |
|
|
House is vacant. Call Landlady Sharon Boland about 30 minutes prior to inspection so she can open up house for you. ###-####. Appliances are inside house. Phone #: ###-#### Inspection requested via web by Mary LaFayette - furnace ac coil co ok
|
MEC20-00357
| Final | 4/27/2020 | 4/28/2020 | 4/28/2020 10:08:25 AM | A | PASS |
|
|
AC: 2019 Phone #: ###-#### Inspection requested via web by Gary Reeves - final ok
|
MEC20-00183
| Final | 4/27/2020 | 4/28/2020 | 4/28/2020 9:01:17 AM | A | PASS |
|
|
Garage code 5513 Phone #: ###-#### Inspection requested via web by santiago ramirez - final ok
|
MEC19-01922
| Mec-Aging Inspection | 4/28/2020 | 4/28/2020 | 4/28/2020 8:05:21 AM | | FAIL |
|
|
Schedule inspection with owner if corrections have been made. Permit was active last on 1-31-20.
|
MEC19-02987
| Mec-Aging Inspection | 4/28/2020 | 4/28/2020 | 4/28/2020 8:03:32 AM | | PASS |
|
|
Doc Permit Expired ok
|
MEC19-02987
| DOC - Permit Expired | 4/28/2020 | 4/28/2020 | 4/28/2020 8:03:15 AM | A | PASS |
|
|
Doc Permit Expired ok permit not active
|