ELE04-01520
| Final | 4/28/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | NR |
|
|
any questions please call Tim Watkins; Phone #: ###-#### Internet Inspection Request from: Jeff Radford met elect, he needs to change the main breaker and provide gfci protection for 120 v recpts. Did not open panel, needs to be looked at. 1 leg of 220 v service has been abandoned, therefore service needs to be 120v 1 phase. 4/29/2005 3:04:24 PM
|
ELE05-00818
| Final | 4/28/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 4/28/2005 at 1:52:13 PM. Contact: ###-####. corrections made, ok to final 4/29/2005 8:00:53 AM
|
ELE04-03683
| Temporary Service | 4/28/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 4/28/2005 at 2:54:31 PM. Contact: ###-####. see added inspection 4/29/2005 9:01:56 AM
|
ELE05-01472
| Rough-In Permanent Service | 4/28/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | PASS |
|
|
brandon ###-#### ric ok, p/s u/g n ok 4/29/2005 8:12:51 AM
|
ELE05-01194
| Final | 4/28/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | PASS |
|
|
DOUG; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa ok to final, signed occupancy card 4/29/2005 9:53:09 AM
|
ELE05-01452
| Permanent Service | 4/29/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | DONE |
|
|
Scheduled by a contractor via Hello! on 4/29/2005 at 7:02:29 AM. Contact: ###-####. 4/29/2005 9:18:49 AM
|
ELE05-01410
| Permanent Service | 4/29/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | CANC |
|
|
Scheduled by a contractor via Hello! on 4/29/2005 at 7:03:56 AM. Contact: ###-####. wrong address 4/29/2005 9:15:20 AM
|
ELE05-01475
| Final | 4/29/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer ok to final 4/29/2005 11:07:26 AM
|
ELE05-01463
| Rough-In Permanent Service | 4/28/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | PASS |
|
|
###-#### dino ric ok p/s u/g n ok 4/29/2005 9:45:57 AM
|
ELE05-01464
| Electrical Rough-In | 4/28/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | FAIL |
|
|
###-#### Verna 4/29/2005 8:14:56 AM called contr, left message, left corr notice, 314.20 boxes shall be flush with surface on outside walls, 210.52(D) recpt shall be within 3' of basin upstairs bath, BCC job id shall be posted 4/29/2005 8:17:20 AM
|
ELE04-03683
| Permanent Service | 4/29/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | PASS |
|
|
p/s u/g n ok
|
ELE05-01411
| Permanent Service | 4/29/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | A | PASS |
|
|
p/s u/g n ok
|
ELE05-00422
| Final | 4/29/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | P | PASS |
|
|
deno ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok to final 4/29/2005 4:29:35 PM
|
ELE05-00739
| Final | 4/29/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | P | PART |
|
|
STEVE FINAL; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy will finish with core and shell, need to sign occupancy card 4/29/2005 1:12:46 PM
|
ELE05-01467
| Permanent Service | 4/28/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | P | PASS |
|
|
p/s u/g exst ok 4/29/2005 1:11:18 PM
|
ELE05-00961
| Final | 4/29/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | P | PASS |
|
|
darrell; Phone #: ###-#### Internet Inspection Request from: Barbara Moore talked to contr, ok to final 4/29/2005 2:08:23 PM
|
ELE05-01424
| Electrical Rough-In | 4/29/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | P | CANC |
|
|
any questions please call Ed Schallock; Phone #: ###-#### Internet Inspection Request from: Jeff Radford wrong call, really t/s 4/29/2005 3:59:42 PM
|
ELE05-01424
| Temporary Service | 4/29/2005 | 4/29/2005 | 4/29/2005 12:00:00 AM | P | PASS |
|
|
any questions please give Ed Schallock a call; Phone #: ###-#### Internet Inspection Request from: Jeff Radford t/s u/g n ok 4/29/2005 2:55:33 PM
|
ELE05-01326
| Final | 4/27/2005 | 4/29/2005 | 4/28/2005 11:50:39 AM | A | CANC |
|
|
rick; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie Disp set to [CANC] by a contractor via Hello! on Apr 28 2005 11:50AM.
|
ELE05-00010
| Final | 4/22/2005 | 4/29/2005 | 4/28/2005 10:42:53 AM | P | CANC |
|
|
We installed a new 20 amp 120 volt circuit to a new receptacle for the above-the-range microwave.Thanks!!!Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell Inspection cancelled from web by: Dan Mitchell
|