Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-04027 ELE-Aging Inspection4/29/20084/29/20084/29/2008 3:12:22 PM DONE
ELE07-04027 DOC - Permit Finaled4/29/20084/29/20084/29/2008 3:12:15 PMPPASS
no permit required for type of work performed
ELE07-03088 Final4/28/20084/29/20084/29/2008 2:20:44 PMPFAIL
SEAN Phone #: ###-#### Internet Inspection Request from: Sean DeLacy corr. called 110.26(D) needs light for indoor panel. 110.26(F) (2) remove bush in front of p/s
ELE08-01040 Electrical Rough-In4/25/20084/29/20084/29/2008 1:22:44 PMPNH
two outlets are ready for inspection, customer will be home after 2:00 pm. Phone #: ###-#### Internet Inspection Request from: gary batten called leaving area P M inspection shall have access at 1: 00 or call inspector ahead of time for access
ELE08-00754 Electrical Rough-In4/29/20084/29/20084/29/2008 1:21:04 PMPPART
jerod Phone #: ###-#### Note: potting compound ok only
ELE08-00040 Final4/29/20084/29/20084/29/2008 1:05:58 PMPPASS
Scheduled by a contractor via Hello! on 4/29/2008 at 9:41:54 AM. Contact: ###-####. ok
ELE07-03780 Final4/28/20084/29/20084/29/2008 10:43:49 AMAPART
Tom Gilbert is the contact on this job, ###-#### Phone #: ###-#### Internet Inspection Request from: Debby Ellis
see added p/s need to check if new cooler tower is listed
ELE07-03780 Permanent Service4/29/20084/29/20084/29/2008 10:42:55 AMAPASS
Tom Gilbert is the contact on this job, ###-#### Phone #: ###-#### Internet Inspection Request from: Debby Ellis
p/s u/g new ok
ELE08-00511 Permanent Service4/28/20084/29/20084/29/2008 9:42:44 AMAPASS
this is for the service on the TI Phone #: ###-#### p/s u/g for meter ok
ELE08-00955 Electrical Rough-In4/28/20084/29/20084/29/2008 9:16:22 AMAFAIL
Repair was made to wiring next to front door. Openings for smoke detectors have been added. Fuse panel has been removed by extension of circuits to new panel. New range and dryer circuits were also installed. Front door code is 1290. Please call Trent at ###-#### with any questions. Thanks. Phone #: ###-#### Internet Inspection Request from: Trent Reagan corr. called r/i only, 250.148 grd W H handy box 314.17 replace front 2 gang switch bo and dryer box broken factory clamps, needs connectors for dryer and WM cables at jbox and handy box seal unused KOs
ELE08-00988 Conference4/28/20084/29/20084/29/2008 8:27:03 AMADONE
Tom Wonacott would like to meet for a conference at 8:00 am Phone #: ###-#### Internet Inspection Request from: gary batten
ELE08-00988 Final4/29/20084/29/20084/29/2008 8:26:52 AMAPASS
Tom Wonacott would like to meet for a conference at 8:00 am Phone #: ###-#### Internet Inspection Request from: gary batten ok
ELE08-00988 Electrical Rough-In4/29/20084/29/20084/29/2008 8:26:33 AMAPASS
Tom Wonacott would like to meet for a conference at 8:00 am Phone #: ###-#### Internet Inspection Request from: gary batten ok