ELE07-04027
| ELE-Aging Inspection | 4/29/2008 | 4/29/2008 | 4/29/2008 3:12:22 PM | | DONE |
|
|
|
ELE07-04027
| DOC - Permit Finaled | 4/29/2008 | 4/29/2008 | 4/29/2008 3:12:15 PM | P | PASS |
|
|
no permit required for type of work performed
|
ELE07-03088
| Final | 4/28/2008 | 4/29/2008 | 4/29/2008 2:20:44 PM | P | FAIL |
|
|
SEAN Phone #: ###-#### Internet Inspection Request from: Sean DeLacy corr. called 110.26(D) needs light for indoor panel. 110.26(F) (2) remove bush in front of p/s
|
ELE08-01040
| Electrical Rough-In | 4/25/2008 | 4/29/2008 | 4/29/2008 1:22:44 PM | P | NH |
|
|
two outlets are ready for inspection, customer will be home after 2:00 pm. Phone #: ###-#### Internet Inspection Request from: gary batten called leaving area P M inspection shall have access at 1: 00 or call inspector ahead of time for access
|
ELE08-00754
| Electrical Rough-In | 4/29/2008 | 4/29/2008 | 4/29/2008 1:21:04 PM | P | PART |
|
|
jerod Phone #: ###-#### Note: potting compound ok only
|
ELE08-00040
| Final | 4/29/2008 | 4/29/2008 | 4/29/2008 1:05:58 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 4/29/2008 at 9:41:54 AM. Contact: ###-####. ok
|
ELE07-03780
| Final | 4/28/2008 | 4/29/2008 | 4/29/2008 10:43:49 AM | A | PART |
|
|
Tom Gilbert is the contact on this job, ###-#### Phone #: ###-#### Internet Inspection Request from: Debby Ellis see added p/s need to check if new cooler tower is listed
|
ELE07-03780
| Permanent Service | 4/29/2008 | 4/29/2008 | 4/29/2008 10:42:55 AM | A | PASS |
|
|
Tom Gilbert is the contact on this job, ###-#### Phone #: ###-#### Internet Inspection Request from: Debby Ellis p/s u/g new ok
|
ELE08-00511
| Permanent Service | 4/28/2008 | 4/29/2008 | 4/29/2008 9:42:44 AM | A | PASS |
|
|
this is for the service on the TI Phone #: ###-#### p/s u/g for meter ok
|
ELE08-00955
| Electrical Rough-In | 4/28/2008 | 4/29/2008 | 4/29/2008 9:16:22 AM | A | FAIL |
|
|
Repair was made to wiring next to front door. Openings for smoke detectors have been added. Fuse panel has been removed by extension of circuits to new panel. New range and dryer circuits were also installed. Front door code is 1290. Please call Trent at ###-#### with any questions. Thanks. Phone #: ###-#### Internet Inspection Request from: Trent Reagan corr. called r/i only, 250.148 grd W H handy box 314.17 replace front 2 gang switch bo and dryer box broken factory clamps, needs connectors for dryer and WM cables at jbox and handy box seal unused KOs
|
ELE08-00988
| Conference | 4/28/2008 | 4/29/2008 | 4/29/2008 8:27:03 AM | A | DONE |
|
|
Tom Wonacott would like to meet for a conference at 8:00 am Phone #: ###-#### Internet Inspection Request from: gary batten
|
ELE08-00988
| Final | 4/29/2008 | 4/29/2008 | 4/29/2008 8:26:52 AM | A | PASS |
|
|
Tom Wonacott would like to meet for a conference at 8:00 am Phone #: ###-#### Internet Inspection Request from: gary batten ok
|
ELE08-00988
| Electrical Rough-In | 4/29/2008 | 4/29/2008 | 4/29/2008 8:26:33 AM | A | PASS |
|
|
Tom Wonacott would like to meet for a conference at 8:00 am Phone #: ###-#### Internet Inspection Request from: gary batten ok
|