Inspections for the day of: Friday, April 29, 2016.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-02432 ELE-Aging Inspection4/29/20164/29/20164/29/2016 4:19:14 PM CANC
ELE12-02127 ELE-Aging Inspection4/29/20164/29/20164/29/2016 4:18:40 PM CANC
ELE12-00814 ELE-Aging Inspection4/29/20164/29/20164/29/2016 4:17:48 PM CANC
ELE16-01174 Conference4/29/20164/29/20164/29/2016 4:13:54 PMPDONE
Zahid Phone #: ###-####
discussed wiring to shed, 30amp feed for welder and light and receptacle. Conduit pre installed under driveway OK will dig to 18" as soon as possible after leaving concrete and maintain depth to shed. GFCI protection of receptacles and disconnect on interior of shed in wall OK. Need to remind of tamper
ELE16-01360 Conference4/29/20164/29/20164/29/2016 3:39:00 PMPDONE
Steve-please call 30 m inutes prior to meet Phone #: ###-####
Discussed the addition of hot tub. 2800 sq. ft house needs service change to larger service to add hot tub. Bond gutter and fence post near tub location.
ELE15-04022 Final4/27/20164/29/20164/29/2016 2:37:55 PMPFAIL
Jake is the contact his cell no. is ###-####. Phone #: ###-#### Inspection requested via web by Shawna Gates
250.30- Common neutral bar and transfer switch, non seperately derived system, Seperate grounds and neutral at generator.
ELE14-00519 ELE-Request for Extension4/29/20164/29/20164/29/2016 12:57:40 PMPPASS
Clark// please call before Phone #: ###-#### Still under construction. Extension OK
ELE16-00801 Electrical Rough-In4/28/20164/29/20164/29/2016 12:49:58 PMPFAIL
Tile floor heat Phone #: ###-#### Inspection requested via web by danny perrine
110.3- Floor heat cable shall be installed as per manufacturers instructions. Cold lead splice shall be enbedded in tile floor.
ELE16-01314 Permanent Service4/29/20164/29/20164/29/2016 12:20:12 PMPPASS
Service energize inspection Phone #: ###-#### Inspection requested via web by April Brown p/s u/g n ok
ELE16-01148 Final4/29/20164/29/20164/29/2016 11:33:34 AMAPASS
For access please call Richie 1/2 hr prior to inspection.###-#### Inspection requested via web by Terry Scott
Final ok
ELE16-00868 Final4/29/20164/29/20164/29/2016 11:20:46 AMAPASS
Daven Story on site. Phone #: ###-#### Inspection requested via web by Brian Caruso Final ok
ELE16-01357 Final4/28/20164/29/20164/29/2016 10:56:03 AMAFAIL
I put the address in as 915 S Curtis Rd and it should be 815 S Curtis Rd - Trlr 71 Boise, id - If you have any questions , please call David Kubik - ###-#### Phone #: ###-#### Inspection requested via web by Charmel Kubik
230.28- Overhead service pole strength. Base of pole has rotte out and needs to be replaced. Make sure drip loop is min of 10' above grade.
362.48- ENT joists shall be of as approved method. ENT to PVC TA joint duct taped.
352.30- PVC conduit shall be secured in place under trailer.
Call and correct address
ELE16-00866 Final4/28/20164/29/20164/29/2016 8:25:37 AMAPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ELE16-01357 Final4/28/20164/29/20164/28/2016 8:45:59 PMACANC
Please call David Kubik - ###-#### if there is any questions Phone #: ###-#### >> Inspection requested via web by Charmel Kubik Inspection cancelled from web by: Charmel Kubik