Inspections for the day of: Friday, April 3, 2015.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRex Boyles
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
GCE15-00052 GCE-Rough-In Permanent Service4/3/20154/3/20154/3/2015 4:35:13 PMPPASS
Andy ###-#### p/s o/h n ok (r/i insp. not needed)
GCE15-00048 GCE-Final4/3/20154/3/20154/3/2015 4:08:35 PMPCANC
Robert ###-#### address should be "East" 39th street. Will inspect loadcenter changeout at next inspection as per Robert
ELE15-00862 Final4/2/20154/3/20154/3/2015 3:27:58 PMPPASS
Crescent Rim condos unit 3-403
Please call Dave for acess ###-#### Phone #: ###-#### Inspection requested via web by Emmet Bushman final ok
ELE15-00174 Final4/3/20154/3/20154/3/2015 2:44:06 PMPNR
Joel Phone #: ###-#### not ready office furniture not on site.
ELE15-00361 Final4/3/20154/3/20154/3/2015 2:06:10 PMPPASS
Robert. Phone #: ###-#### Inspection requested via web by Sean DeLacy final ok
ELE15-00892 Electrical Rough-In4/3/20154/3/20154/3/2015 2:05:19 PMPPASS
Robert. Phone #: ###-#### Inspection requested via web by Sean DeLacy r/i ceiling ok
ELE14-03517 Electrical Rough-In4/2/20154/3/20154/3/2015 1:23:01 PMPPASS
exterior walls rough-in Phone #: ###-#### Inspection requested via web by Brandon Winters r/i exterior walls 1st and 2nd flr ok
ELE15-00888 Electrical Rough-In4/2/20154/3/20154/3/2015 1:05:49 PMPNR
Need an ok to cover. Juli the owner should be there all PM, Call Jimmy for questions @ ###-#### Phone #: ###-#### Inspection requested via web by John Edwards not ready
ELE15-00197 Final4/2/20154/3/20154/3/2015 12:28:44 PMAPASS
We are requesting a final inspection for tomorrow 4/3/15 during the am. Our onsite contact is Rod @ ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Clint Tate final ok
ELE14-03246 Electrical Rough-In4/2/20154/3/20154/3/2015 11:51:25 AMAPASS
Towers 3 ; 4 Floors 2 ; 3 floor units ; lobby. Phone #: ###-#### Inspection requested via web by Sean DeLacy r/i tower 4 rms. 300 thru 305 and lobby and office walls ok
ELE15-00869 Electrical Rough-In4/2/20154/3/20154/3/2015 10:31:50 AMAPASS
Phone #: ###-#### Inspection requested via web by Eric Schroeder r/i kitchen ok
ELE15-00889 Conference4/2/20154/3/20154/3/2015 10:04:22 AMADONE
Please Call before you go. Phone #: ###-#### Inspection requested via web by HZ ZAHIC discuss rewiring old apt. in nm cable with Hito
ELE15-00450 Electrical Rough-In4/2/20154/3/20154/3/2015 9:29:26 AMAPASS
Underground // Brian Phone #: ###-#### u. ground conduits to de watering pumps ok see plans
GCE15-00051 GCE-Permanent Service3/31/20154/3/20154/3/2015 8:54:17 AMAFAIL
Brian ###-#### Add supplemental ground rod, add intersystem ground bar, #12 conductors tapped off 1oo amp breaker feeding 2 underground conduits without overcurrent protection, overhead feeders to mobile home have no strain releif and don't meet clearances, lots of debris in old meter main and no dead front on meter main.
ELE15-00877 Temporary Service4/2/20154/3/20154/3/2015 8:15:41 AMAPASS
Temp Power pole. Robert is the contact. Phone #: ###-#### Inspection requested via web by Buster Bowen t/s u/g n ok
ELE13-00519 ELE-Aging Inspection4/3/20154/3/20154/3/2015 7:27:37 AM DONE
too busy
ELE12-03157 ELE-Aging Inspection4/3/20154/3/20154/3/2015 7:27:08 AM DONE
too busy
ELE12-01987 ELE-Aging Inspection4/3/20154/3/20154/3/2015 7:26:39 AM DONE
too busy
ELE14-03517 Electrical Rough-In4/2/20154/3/20154/2/2015 3:17:42 PMACANC
exterior wall rough-in Phone #: ###-#### >> Inspection requested via web by Brandon Winters Inspection cancelled from web by: Brandon Winters