Inspections for the day of: Friday, April 3, 2015.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorEric Strole
TitlePLM/MEC-INSPECTOR
Phone #794-7913
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM15-00087 Plumbing Rough-in4/3/20154/3/20154/3/2015 3:21:39 PMPFAIL
please call Dave. Thank YOU! Phone #: ###-#### Inspection requested via web by Rhonda Marcum-Units 218 thru 418, 217 thru 417, 219 thru 419, 220 thru 440, 222 thru 422 & 224 thru 424- Missing some nailplates, Need to replace drop ear 90's on tub/shower valves, need to fix flat drains and backgraded vents and vent that is below flood level rim and retest.
MEC15-01412 Rough-in4/1/20154/3/20154/3/2015 3:04:13 PMPPASS
Inspection requested via web by Jason Robinson
MEC15-01398 Final4/3/20154/3/20154/3/2015 3:03:40 PMPPASS
Please call Random @ ###-#### prior to inspection Phone #: ###-#### Inspection requested via web by Tami Kelly
PLM14-03596 Final3/30/20154/3/20154/3/2015 3:03:19 PMPPASS
Please call prior to inspection Phone #: ###-#### Inspection requested via web by Mary LaFayette
MEC15-01329 Final4/3/20154/3/20154/3/2015 1:54:55 PMPFAIL
Please call the homeowner, Nick, @ ###-#### prior to inspection Phone #: ###-#### Inspection requested via web by Tami Kelly-Need upper combustion air and need to pull dampers out of lower combustion air register
PLM14-01841 Plumbing Rough-in4/2/20154/3/20154/3/2015 1:35:26 PMPPART
BRIAN IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER-Test on section of water pass.
PLM15-00924 Sprinkler (Final)4/1/20154/3/20154/3/2015 11:55:39 AMAPASS
Please contact JR at ###-#### or Kelton ###-####
They will need to be present to turn on the water for inspection.
Thanks! Phone #: ###-#### Inspection requested via web by Franz Witte
PLM14-02923 PLM-Aging Inspection4/3/20154/3/20154/3/2015 11:55:08 AM PASS
PLM14-02923 DOC - Permit Finaled4/3/20154/3/20154/3/2015 11:54:50 AMPPASS
PLM15-00090 Final4/2/20154/3/20154/3/2015 10:47:32 AMAPASS
Phone #: ###-#### Inspection requested via web by Rob Bristol
PLM15-01014 Plumbing Rough-in4/2/20154/3/20154/3/2015 10:31:45 AMAPASS
EXISTING RESIDENCE GARAGE CODE #8647 Phone #: ###-#### Inspection requested via web by Semsudin Konjuhovac
PLM14-00292 Final4/2/20154/3/20154/3/2015 10:17:37 AMAPASS
Call 10-15 mins before // Steve Phone #: ###-####
PLM15-00087 Water and/or Sewer4/3/20154/3/20154/3/2015 10:02:06 AMAFAIL
Need to replace all drop ear 90's in building becouse thay are not approved for potable water.
PLM15-00035 Plumbing Rough-in4/3/20154/3/20154/3/2015 10:01:29 AMAFAIL
Need to replace all drop ear 90's in building becouse thay are not approved for potable water.
PLM15-00036 Plumbing Rough-in4/3/20154/3/20154/3/2015 10:00:45 AMAFAIL
Need to replace all drop ear 90's in building becouse thay are not approved for potable water.
PLM15-00034 Plumbing Rough-in4/3/20154/3/20154/3/2015 9:59:45 AMAFAIL
Need to replace all drop ear 90's in building becouse thay are not approved for potable water.
PLM15-00033 Plumbing Rough-in4/3/20154/3/20154/3/2015 9:55:06 AMAFAIL
Need to replace all drop ear 90's in building becouse thay are not approved for potable water.
PLM15-00035 Plumbing Rough-in4/3/20154/3/20154/3/2015 9:48:19 AMAPART
Test on water in living units pass and corrections to carriers ok, still need test on roof drains.
PLM15-01011 Water and/or Sewer4/2/20154/3/20154/3/2015 9:41:46 AMAPASS
Phone #: ###-#### Inspection requested via web by Darren Wood
PLM15-01011 DOC - Permit Finaled4/3/20154/3/20154/3/2015 9:41:00 AMPPASS
PLM15-01012 Water Heater Final4/2/20154/3/20154/3/2015 9:23:46 AMAPASS
Contact is Chris. Phone #: ###-#### Inspection requested via web by Julie Dobransky
PLM15-00924 Sprinkler (Final)4/1/20154/3/20154/1/2015 3:00:44 PMACANC
Call Kelton Bice ###-#### for on site contact. Will be ready for inspection Friday a.m. Phone #: ###-#### >> Inspection requested via web by Franz Witte Inspection cancelled from web by: Franz Witte