Inspections for the day of: Monday, April 30, 2012.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorDaryl DeGrange
TitleELE-INSPECTION SUPV
Phone #794-1379
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC10-00627 Aging Inspection4/30/20124/30/20125/3/2012 1:14:07 PM PASS
still under construction
ELE11-01876 ELE-Aging Inspection4/30/20124/30/20125/2/2012 1:52:53 PM PASS
still under construction
GCE12-00040 GCE-Final4/30/20124/30/20124/30/2012 4:46:56 PMPFAIL
(Mandatory Inspection)
Danny @ ###-####
Requested an afternoon inspection today. NEC 110.3(B) Label and listed equipment by a third party
ELE12-00915 Electrical Rough-In4/30/20124/30/20124/30/2012 3:50:34 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok cover walls 1-3 link pantry
ELE12-00560 Final4/30/20124/30/20124/30/2012 2:46:24 PMPPASS
Mike Phone #: ###-#### final ok
ELE11-02831 Final4/30/20124/30/20124/30/2012 2:35:28 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Dan Rohl final ok
ELE12-00913 Permanent Service4/30/20124/30/20124/30/2012 2:08:31 PMPPASS
SERVICE INSPECTION ON SHOP PANEL Phone #: ###-#### >> Inspection requested via web by John VanZandt p/s o/h rec ok additional ground rod and panel labeled for final
ELE11-02494 Final4/29/20124/30/20124/30/2012 1:46:11 PMPFAIL
Phone #: ###-#### >> Inspection requested via web by Julie Schroder NEC. 408.7 Unused openings for circuit breakers shall be closed using identified closures
ELE12-00918 Final4/30/20124/30/20124/30/2012 1:16:20 PMPPASS
final ok
ELE12-00918 Electrical Rough-In4/30/20124/30/20124/30/2012 1:08:54 PMPPASS
Phone #: ###-#### >> Inspection requested via web by PAT MILLER rough-in ok A/C unit
ELE12-00832 Rough-In Permanent Service4/30/20124/30/20124/30/2012 12:26:49 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Alan Lusk rough-in p/s u/g n ok
ELE11-02657 Electrical Rough-In4/27/20124/30/20124/30/2012 10:35:32 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Brandon Winters rough-in ok cover east core of main floor
ELE12-00895 Rough-In Permanent Service4/27/20124/30/20124/30/2012 9:37:16 AMPPASS
Phone #: ###-#### >> Inspection requested via web by Kathy Smith rough-in p/s u/g n ok
ELE12-00908 Temporary Service4/27/20124/30/20124/30/2012 9:20:44 AMAFAIL
Jason Phone #: ###-#### NEC 250.53 Grounding electrode shall be flush with or below ground level
ELE12-00878 Rough-In Permanent Service4/27/20124/30/20124/30/2012 9:00:42 AMAPASS
THANKS, BILL Phone #: ###-#### >> Inspection requested via web by Bob Glenn rough-in p/s o/h n ok
ELE12-00911 Rough-In Permanent Service4/29/20124/30/20124/30/2012 8:34:05 AMAPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov rough-in p/s u/g n ok
ELE12-00910 Rough-In Permanent Service4/29/20124/30/20124/30/2012 8:31:56 AMAPASS
Phone #: ###-#### >> Inspection requested via web by daniel bibikov rough-in p/s u/g n ok