ELE10-02472
| ELE-Aging Inspection | 4/30/2018 | 4/30/2018 | 5/1/2018 8:27:54 AM | | DONE |
|
|
waiting on homeowner
|
ELE18-01613
| Permanent Service | 4/30/2018 | 4/30/2018 | 4/30/2018 2:58:48 PM | P | PASS |
|
|
Needs final for permanent service***Please do inspection anytime after 2:30 if possible Phone #: ###-#### Inspection requested via web by Same Electric...p/s o/h reconnect ok
|
ELE18-01554
| Electrical Rough-In | 4/30/2018 | 4/30/2018 | 4/30/2018 2:30:29 PM | P | PASS |
|
|
Brian Phone #: ###-####...rough ok to cover
|
ELE18-00245
| Final | 4/27/2018 | 4/30/2018 | 4/30/2018 2:08:57 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Todd Hall...ok to final
|
ELE18-00244
| Final | 4/27/2018 | 4/30/2018 | 4/30/2018 2:08:17 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Todd Hall...ok to final
|
ELE18-01612
| Temporary Service | 4/29/2018 | 4/30/2018 | 4/30/2018 12:29:00 PM | A | PASS |
|
|
Overhead Temp Power Pole Phone #: ###-#### Inspection requested via web by Lynn Cable...t/s o/h new ok
|
ELE17-04040
| Final | 4/30/2018 | 4/30/2018 | 4/30/2018 11:58:29 AM | A | PASS |
|
|
scheduled to final out permit...work was taken over by another electrician using permit # ELE18-01609
|
ELE18-01609
| Final | 4/27/2018 | 4/30/2018 | 4/30/2018 11:49:53 AM | A | FAIL |
|
|
rough and service inspected under permit #ELE17-04040. Previous electrician completed work up to the trim stage. Access code 8922 Phone #: ###-#### Inspection requested via web by Paula Gratiot...
1) 2' wall space shall have an outlet..pantry/fridge wall...210.52(A)(2)
2) counters in pantruy/kitchen/dining shall have outlets required by 210.52(C)(1)-(C)(5)...pantry
|
ELE18-01583
| Final | 4/28/2018 | 4/30/2018 | 4/30/2018 10:45:58 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by Keith Olstrom...not ready for final at this time...needed perm service inspection
|
ELE18-01583
| Permanent Service | 4/30/2018 | 4/30/2018 | 4/30/2018 10:45:21 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Keith Olstrom...p/s u/g reconnect ok
|
ELE18-01145
| Final | 4/30/2018 | 4/30/2018 | 4/30/2018 9:45:25 AM | P | PASS |
|
|
Austin will be there as well as homeowner. Phone #: ###-#### Inspection requested via web by BRS Permitting...OCPD, labelling, and disconnect ok
|
ELE18-01145
| Electrical Rough-In | 4/25/2018 | 4/30/2018 | 4/30/2018 9:44:52 AM | A | PASS |
|
|
Austin will be there as well as homeowner. Phone #: ###-#### Inspection requested via web by BRS Permitting...UL listed equipment verified
|
ELE18-01607
| Final | 4/27/2018 | 4/30/2018 | 4/30/2018 9:23:01 AM | A | FAIL |
|
|
Please call March at ###-#### for access. If you have any questions please call Jeremiah at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell.. 1..romex shall not be exposed to physical damage..334.15
2..romex shall not be used in wet or damp locations...334.12(B)
3..outlets shall be of weather resistant type..406.9
4..S/O cord shall be rated heavy duty use to wire air compressor or protected from physical damage...needs replaced-is all ready weathered and cracked and cannot be used to wire compressor 5..access to panel is required...unable to verify breaker...panels shall have 3' clearance..readily accessible meaning no tool...110.26
|
ELE18-01598
| Rough-In Permanent Service | 4/27/2018 | 4/30/2018 | 4/30/2018 8:31:07 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn...rough ok to cover..p/s u/g new ok
|