ELE19-00685
| Final | 4/30/2019 | 4/30/2019 | 4/30/2019 3:06:36 PM | P | PASS |
|
|
garage code 1957e Phone #: ###-#### Inspection requested via web by Alan Lusk Final ok
|
ELE19-00652
| Final | 4/30/2019 | 4/30/2019 | 4/30/2019 2:14:47 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Lee VanSchoiack 210.8- All receptacle outlets located with in 6' of a sink shall have GFCI protection. Bar. 22/24 2 pole 20 for kitchen not tripping. 300.22- Cooler penatrations shall be sealed. 408.4- Circuit directory shall be complete.
|
ELE18-02369
| Electrical Rough-In | 4/29/2019 | 4/30/2019 | 4/30/2019 1:39:02 PM | P | PASS |
|
|
1st ; 2nd Floor Ceilings. Generator Grounding Electrode. Call Joey C. prior to arrival. Phone #: ###-#### Inspection requested via web by Scott Campbell Generator GES and level 1 and 2 corridor grid rough in ok cover
|
ELE19-00499
| Electrical Rough-In | 4/30/2019 | 4/30/2019 | 4/30/2019 1:07:23 PM | P | PASS |
|
|
Floor heat master bathroom and closet Phone #: ###-#### Inspection requested via web by Greg Idsinga Floor heat area noted rough in ok cover
|
ELE19-00913
| Final | 4/29/2019 | 4/30/2019 | 4/30/2019 11:58:26 AM | A | NR |
|
|
Jake Phone #: ###-#### Tenant needing to occupy, hoping for basement, but too many unfinished wiring in areas needed. All wiring shall be terminate in a box or piece of equipment to avoid accidental contact. Shall provide inspector access to all boxes for testing. Recall when ready.
|
ELE19-01331
| Electrical Rough-In | 4/29/2019 | 4/30/2019 | 4/30/2019 11:10:16 AM | A | PASS |
|
|
spec sheets have been sent that describe the lights. a final for this project will also be needed. thank you. Phone #: ###-#### Inspection requested via web by Candy Magly Listing confirmed. Rough in ok
|
ELE19-01331
| Final | 4/30/2019 | 4/30/2019 | 4/30/2019 11:09:58 AM | P | PASS |
|
|
spec sheets have been sent that describe the lights. a final for this project will also be needed. thank you. Phone #: ###-#### Inspection requested via web by Candy Magly Final ok
|
ELE19-01329
| Electrical Rough-In | 4/29/2019 | 4/30/2019 | 4/30/2019 11:09:11 AM | A | PASS |
|
|
We will need a final at the same time. This was only a lighting retrofit and the work is complete. Spec sheets have been sent for guideline. Phone #: ###-#### Inspection requested via web by Candy Magly Listing confirmed. Rough in ok
|
ELE19-01329
| Final | 4/30/2019 | 4/30/2019 | 4/30/2019 11:08:40 AM | P | PASS |
|
|
We will need a final at the same time. This was only a lighting retrofit and the work is complete. Spec sheets have been sent for guideline. Phone #: ###-#### Inspection requested via web by Candy Magly Final ok
|
ELE19-00872
| Final | 4/29/2019 | 4/30/2019 | 4/30/2019 10:32:28 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Don Conley Final ok
|
ELE19-01443
| Rough-In Permanent Service | 4/29/2019 | 4/30/2019 | 4/30/2019 9:43:57 AM | A | PASS |
|
|
Please contact Mike with any questions or concerns ###-#### Phone #: ###-#### Inspection requested via web by Bob Glenn No power to fireplace. Rough in ok cover p/s u/g n ok
|