MEC19-01262
| Final | 4/23/2019 | 4/30/2019 | 4/30/2019 3:52:20 PM | P | NR |
|
|
Please call Dana at ###-#### when in route. Phone #: ###-#### Inspection requested via web by Sabrina DeHority - called owner and she said the work hadn't been finished yet. That the gas company was rescheduled for a different time and work will be finished next week. Schedule inspection when work is completed
|
MEC19-01497
| Rough-in | 4/29/2019 | 4/30/2019 | 4/30/2019 3:43:38 PM | P | PASS |
|
|
Please call before going to the job site.
Thanks Phone #: ###-#### Inspection requested via web by Dennis Fox - R/I ok
|
MEC19-01700
| Rough-in | 4/30/2019 | 4/30/2019 | 4/30/2019 2:28:45 PM | P | FAIL |
|
|
Olg Phone #: ###-#### - 1st floor west side has a unit with a dryer vent not finished and terminated out the roof - 2nd floor chase between two bathrooms has ducts that need firecaulked - 3rd floor line set in breeze way needs firecaulked
|
MEC18-05532
| Rough-in | 4/30/2019 | 4/30/2019 | 4/30/2019 2:25:32 PM | P | PASS |
|
|
Olg Phone #: ###-#### - west side duct seal ok - west side R/I ok for cover
|
MEC19-00904
| Rough-in | 4/29/2019 | 4/30/2019 | 4/30/2019 1:20:46 PM | P | PASS |
|
|
field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney - R/I ok
|
MEC19-00904
| Pressure Test | 4/29/2019 | 4/30/2019 | 4/30/2019 1:20:30 PM | P | PASS |
|
|
field super: Jason Landers Phone #: ###-#### Inspection requested via web by Lisa Whitney - 20lb gas pressure test ok - tagged meter location
|
MEC19-00740
| Final | 4/29/2019 | 4/30/2019 | 4/30/2019 12:02:29 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft - fireplace final ok
|
MEC19-00801
| Final | 4/29/2019 | 4/30/2019 | 4/30/2019 12:01:47 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft - fireplace final ok
|
MEC19-00716
| Final | 4/29/2019 | 4/30/2019 | 4/30/2019 10:19:40 AM | A | PASS |
|
|
JAMES IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - final ok -will sign occ card when other mechanical permit is finaled
|
MEC19-00716
| Rough-in | 4/29/2019 | 4/30/2019 | 4/30/2019 10:17:40 AM | A | PASS |
|
|
JAMES IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - R/I ok
|
MEC19-00716
| Pressure Test | 4/29/2019 | 4/30/2019 | 4/30/2019 10:17:21 AM | A | PASS |
|
|
JAMES IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER - 60lb gas pressure test ok
|
MEC19-01698
| Rough-in | 4/25/2019 | 4/30/2019 | 4/30/2019 9:55:03 AM | A | PASS |
|
|
RICK ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza - R/I ok for fireplace moving down from original location
|
MEC19-01698
| Pressure Test | 4/25/2019 | 4/30/2019 | 4/30/2019 9:53:11 AM | A | PASS |
|
|
RICK ###-#### Phone #: ###-#### Inspection requested via web by Mike Almanza - existing gas line was moved down for the new location of fireplace. Bubble test change in gas line
|
MEC19-01535
| Pressure Test | 4/29/2019 | 4/30/2019 | 4/30/2019 9:20:50 AM | A | PASS |
|
|
Rough in Inspection requested via web by Lynn Johnston - pressure test passed on last inspection
|
MEC19-01535
| Rough-in | 4/30/2019 | 4/30/2019 | 4/30/2019 9:19:55 AM | A | PASS |
|
|
Rough in Inspection requested via web by Lynn Johnston - R/I ok
|
MEC19-01707
| Pressure Test | 4/29/2019 | 4/30/2019 | 4/30/2019 9:04:44 AM | A | PASS |
|
|
Inspection requested via web by Don Dowers - 20lb gas pressure test ok - tagged meter location
|
MEC19-01740
| Rough-in | 4/29/2019 | 4/30/2019 | 4/30/2019 8:48:02 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Shoecraft - fireplace width framing needs to be 37" min - fireplace clearance on sides needs to be 1/2"
|
MEC18-04348
| Mec-Aging Inspection | 4/30/2019 | 4/30/2019 | 4/30/2019 8:12:40 AM | | DONE |
|
|
Called TML and talked with Marisa about their mechancial aging permit. If corrections have been made schedule inspection with homeowner. permit will expire at next mechanical aging inspection
|
MEC16-05348
| Mec-Aging Inspection | 4/30/2019 | 4/30/2019 | 4/30/2019 8:05:43 AM | | DONE |
|
|
WIP
|