Inspections for the day of: Friday, April 4, 2003.
Number of inspections: 9
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE02-01900 Extend Permit 180 days 4/4/20034/4/2003 12:00:00 AM DONE
work still in progress
ELE03-00016 ELE-Aging Inspection4/4/20034/4/20034/4/2003 12:00:00 AM FAIL
cor. posted called needs disconnect could not locate? 600.5(C)(3) needs nipple welded to pole shall provide box and conduit for splices and opne wiring, inside of sign not a approved enclosure 4/4/2003 3:24:38 PM
ELE03-00164 Electrical Rough-In4/1/20034/4/20034/4/2003 12:00:00 AMAFAIL
RICHARD; Phone #: ###-#### Internet Inspection Request from: Darla Downs cor. met with owner 300.4, 300.14, 110.14 4/4/2003 8:51:06 AM
ELE03-00346 Electrical Rough-In4/3/20034/4/20034/4/2003 12:00:00 AMACANC
Scheduled by a contractor via Hello! on 4/3/2003 at 4:08:32 PM. Contact: ###-####. contractor called in wrong PM# 4/4/2003 12:07:35 PM
ELE03-00966 Final4/3/20034/4/20034/4/2003 12:00:00 AMAFAIL
Scheduled by a contractor via Hello! on 4/3/2003 at 5:06:32 PM. Contact: ###-####. cor. and $42.00 fee due posted 300.10,230.24(A), 680.26(A)(B),680.22(A)(3), 250.8,250.24 grd servive not sub panel grd or bond as 250.52,or 250.104 states, 110.3 cut sheetrock at sub panel so cover fits properly 4/4/2003 9:58:05 AM
ELE03-00592 Final4/4/20034/4/20034/4/2003 12:00:00 AMPFAIL
dave; Phone #: ###-#### Internet Inspection Request from: Darla Downs cor. fee due posted called needs 20 amp laundry outlet 410.8 clearence , 250.104 bond new hot and cold new water system job not ready 4/4/2003 2:27:43 PM
ELE03-00236 Final4/4/20034/4/20034/4/2003 12:00:00 AMPPASS
###-#### ok 4/4/2003 1:09:14 PM
ELE02-03818 Permanent Service4/4/20034/4/20034/4/2003 12:00:00 AMPPASS
###-#### p/s u/g new ok 4/4/2003 4:09:45 PM
ELE02-02861 Final4/3/20034/4/20034/3/2003 2:27:39 PMACANC
Scheduled by a contractor via Hello! on 4/3/2003 at 12:35:00 PM. Contact: ###-####. Disp set to [CANC] by a contractor via Hello! on Apr 3 2003 2:27PM.