PLM03-00696
| Water and/or Sewer | 4/3/2003 | 4/4/2003 | 4/4/2003 12:00:00 AM | A | PASS |
|
|
water line only ###-####- patty
|
PLM02-02459
| Final | 4/3/2003 | 4/4/2003 | 4/4/2003 12:00:00 AM | A | PASS |
|
|
ROBERT; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|
PLM03-00869
| Water and/or Sewer | 4/3/2003 | 4/4/2003 | 4/4/2003 12:00:00 AM | A | PASS |
|
|
GLEN; Phone #: ###-#### Internet Inspection Request from: Darla Downs
|
PLM03-00877
| Water and/or Sewer | 4/3/2003 | 4/4/2003 | 4/4/2003 12:00:00 AM | A | FAIL |
|
|
air test failed contractor to recall when ready note called contractor 4/4/2003 9:32:33 AM
|
PLM03-00252
| Final | 4/4/2003 | 4/4/2003 | 4/4/2003 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 4/4/2003 at 8:20:36 AM. Contact: ###-####. need to have premise protection certified 2. expansiontank under sized need to be st-12 3. need heat trap nipples on water heater hot and cold side 4. need to pipe t&p to approved drain or to outside 5.need strainer for floor drain by water heater 6. need protective cover,s on handicapp laves 7.fix leak on east downstaires water closet 8. need to permit sprinkler backflow protection and inspected before final inspection 4/4/2003 3:07:03 PM
|