Inspections for the day of: Tuesday, April 4, 2006.
Number of inspections: 5
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03565 Final4/3/20064/4/20064/4/2006 11:05:10 AMANR
Rick; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong corr. overhang on island more than 6" garage locked called
ELE05-03853 Rough-In Permanent Service3/31/20064/4/20064/4/2006 10:14:26 AMAFAIL
###-#### Internet Inspection Request from: Bob Glenn corr. called 300.4 nail plates and 11/4" 225.31,36 needs main disconnect at house service, 210.52(C)(1) counter outlet spcing right and left of sink, 314,17 (A&C) replace 2,3,4 gang boxes with broken clamps, 334.30 shall not staple romex on edge 314.43 no nails allowed in plastic boxes outside boxes called left message
ELE05-04401 ELE-Aging Inspection4/4/20064/4/20064/4/2006 9:21:05 AM PART
called contractor he will check status, and schedule final
ELE05-04624 Final4/4/20064/4/20064/4/2006 8:57:40 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange ok
ELE05-04625 Final4/4/20064/4/20064/4/2006 8:57:24 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Daryl DeGrange ok