Inspections for the day of: Wednesday, April 4, 2007.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-04716 ELE-Aging Inspection4/4/20074/4/20074/9/2007 9:28:22 AM DONE
see final
ELE06-04676 ELE-Aging Inspection4/4/20074/4/20074/9/2007 8:57:28 AM DONE
see final
ELE07-01114 Electrical Rough-In4/4/20074/4/20074/4/2007 4:06:56 PMPPART
Scheduled by a contractor via Hello! on 4/4/2007 at 10:22:13 AM. Contact: ###-####. ok to cover u/g for pool only, no u/g to pool equip yet
ELE06-03238 Electrical Rough-In4/3/20074/4/20074/4/2007 3:30:49 PMPPASS
david; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ric ok
ELE07-01101 Electrical Rough-In4/4/20074/4/20074/4/2007 2:46:30 PMPPART
Mike swimming pool; Phone #: ###-#### Internet Inspection Request from: Stacie Backus corrections made, ok to cover u/g from house to pool equip and pool light and cover
ELE07-00154 Electrical Rough-In4/4/20074/4/20074/4/2007 2:07:22 PMPPART
Adam; Phone #: ###-#### Internet Inspection Request from: Stacie Backus ok to cover under deck lights, called contr about staples
ELE06-04309 Final4/4/20074/4/20074/4/2007 1:17:06 PMPPASS
CONTACT: ERIC COBISKEY Phone #: ###-#### ok to final
ELE07-01092 Conference4/4/20074/4/20074/4/2007 1:07:05 PMPDONE
CALL MORGAN 20 MIN PRIOR TO GOING TO SITE Phone #: ###-#### talked about service for fire pump, grounding, etc.
ELE06-04457 Electrical Rough-In4/3/20074/4/20074/4/2007 10:51:06 AMAPART
bob - southwing; Phone #: ###-#### Internet Inspection Request from: Victoria Beall nurses station ceiling ok to cover
ELE07-00449 Permanent Service4/3/20074/4/20074/4/2007 10:11:56 AMAFAIL
Please call at least a half hour prior to inspection so he can meet ya there--Rocky ###-#### met elect, service over roof shall be 8' above surface, NEC 230.24(A)
ELE07-01092 Conference4/4/20074/4/20074/4/2007 10:01:23 AMPCANC
MORGAN Phone #: ###-#### Inspection cancelled from web by: Sean DeLacy
ELE07-01084 Conference4/2/20074/4/20074/4/2007 9:49:23 AMADONE
douglas ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith met elect, reviewed work not inspected by others and requirement to bring up to code.
ELE07-01103 Final4/3/20074/4/20074/4/2007 9:10:24 AMAPASS
electrician- Nick Felsted ###-####
customer- Idaho athletic Club ###-#### Phone #: ###-#### ok to final
ELE07-01060 Rough-In Permanent Service4/3/20074/4/20074/4/2007 8:58:11 AMAPASS
Building North West corner ready for rough in and permanent Service 2555 S. Five mile Thanks Brad Phone #: ###-#### ric ok, p/s u/g n ok
ELE06-03427 Final4/3/20074/4/20074/4/2007 8:35:20 AMAFAIL
mike; Phone #: ###-#### Internet Inspection Request from: Victoria Beall called, left corr notice, 110.26(F)(1) dedicated electrical space shall be 6' over panels, 314.27 floor boxes shall be listed specifically for receptacles in floor, BCC recepts shall operate
ELE07-01098 Conference4/3/20074/4/20074/4/2007 8:04:11 AMADONE
PLEASE CONTACT RON 20 MINS. PRIOR TO INSPECTION THANK YOU Phone #: ###-#### talked about load-bank install, old gen-set ok if not worked on directly, work will be done out of j-box, looked at site
ELE07-00889 Electrical Rough-In4/3/20074/4/20074/3/2007 3:58:29 PMAPART
lorren - first thing in the morning please - underground ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith contr called and said ready later, 4" has 2 90's and stops at east and south of bldg, power goes straight to west, ok to cover, told to use fines for backfill, no rocks