Inspections for the day of: Thursday, April 4, 2013.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE09-01570 ELE-Aging Inspection4/4/20134/4/20134/8/2013 3:08:00 PM DONE
still under construction
ELE12-02163 Final4/4/20134/4/20134/5/2013 8:13:10 AMPPASS
Phone #: ###-#### >> Inspection requested via web by Roy Kay Final ok
ELE12-02982 Electrical Rough-In4/3/20134/4/20134/4/2013 2:21:55 PMPPASS
tony Phone #: ###-#### Parking garage ceiling pour marked on print. Rough in ok cover
ELE13-00171 Final4/4/20134/4/20134/4/2013 1:37:25 PMPPASS
please give me half an hour notice to insure access thanks shaun ###-#### Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Final ok
GCE13-00051 GCE-Rough-In4/3/20134/4/20134/4/2013 1:35:44 PMAPASS
Jerry @ ###-#### Under ground rough in ok cover
ELE13-00530 Final4/4/20134/4/20134/4/2013 12:52:26 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Shaun Kirkman Detached garage final ok
ELE13-00738 Final4/4/20134/4/20134/4/2013 12:23:48 PMPPASS
Phone #: ###-#### >> Inspection requested via web by PAT MILLER Final ok
ELE13-00803 Electrical Rough-In4/4/20134/4/20134/4/2013 12:02:10 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Dan Rohl Basement cans and outlets rough in ok cover
ELE13-00752 Final4/3/20134/4/20134/4/2013 11:51:20 AMACANC
Phone #: ###-#### >> Inspection requested via web by michael hunt
needed permanent service
ELE13-00752 Permanent Service4/4/20134/4/20134/4/2013 11:50:25 AMPPASS
Phone #: ###-#### >> Inspection requested via web by michael hunt
p/s o/h n ok
ELE12-02165 Final4/4/20134/4/20134/4/2013 11:28:44 AMPCANC
Please call 30 minutes before Phone #: ###-#### >> Inspection requested via web by Don Conley Contractor called to inform job not accessible
ELE13-00721 Rough-In Permanent Service4/4/20134/4/20134/4/2013 11:23:01 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by daniel bibikov
210.52- Nook- receptical not located with in 6' of door on right side.
250.96- 3/0 boxes- all metal non current carrying parts shall be bonded.
300.4- bored holes in framing member shall be protected from physical damage by nail plates.
Bedroom circuit not complete.
ELE13-00770 Electrical Rough-In4/3/20134/4/20134/4/2013 10:15:48 AMAPASS
Contact: Brian Giacomino, underground inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden Underground rough in ok cover
GCE13-00048 GCE-Rough-In4/3/20134/4/20134/4/2013 9:49:52 AMACANC
Henry @ ###-#### Job rescheduled
ELE13-00793 Temporary Service4/3/20134/4/20134/4/2013 9:30:22 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Darryn Coburn
50 amp 240 volt circuit requires GFCI protection
GCE13-00050 GCE-Final4/3/20134/4/20134/4/2013 9:03:24 AMACANC
Jerry @ ###-#### Needed permanent service
GCE13-00050 GCE-Rough-In Permanent Service4/4/20134/4/20134/4/2013 9:01:34 AMPPASS
Jerry @ ###-#### Permanent service rough in ok p/s u/g n ok
GCE13-00016 GCE-Final4/3/20134/4/20134/4/2013 8:38:44 AMAPASS
David @ ###-#### Final ok