ELE12-00329
| ELE-Aging Inspection | 4/4/2013 | 4/4/2013 | 4/8/2013 9:41:41 AM | | DONE |
|
|
see final
|
ELE12-01885
| Electrical Rough-In | 4/3/2013 | 4/4/2013 | 4/4/2013 3:19:42 PM | P | PASS |
|
|
Ceiling in Lexus Sales Area Phone #: ###-#### >> Inspection requested via web by Kerri Hamilton rough-in ok cover ceiling grid
|
ELE12-02726
| Electrical Rough-In | 4/4/2013 | 4/4/2013 | 4/4/2013 2:43:24 PM | P | PASS |
|
|
Underground -Max Phone #: ###-#### rough-in ok cover 5 24 in. dia pole base
|
ELE13-00805
| Electrical Rough-In | 4/4/2013 | 4/4/2013 | 4/4/2013 2:31:43 PM | P | PASS |
|
|
Just inspection on a few switches and outlets. Chris is contact. Phone #: ###-#### >> Inspection requested via web by Chris Chesnut rough-in ok cover walls and hard lid
|
ELE13-00804
| Electrical Rough-In | 4/4/2013 | 4/4/2013 | 4/4/2013 2:08:02 PM | P | PASS |
|
|
call when on way//ug insp//Toli Phone #: ###-#### rough-in ok cover concrete encased electrode
|
ELE13-00756
| Permanent Service | 4/3/2013 | 4/4/2013 | 4/4/2013 2:04:31 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Neal Rumsey p/s u/g rec ok
|
ELE13-00263
| Electrical Rough-In | 4/4/2013 | 4/4/2013 | 4/4/2013 12:42:49 PM | P | PASS |
|
|
Lobby front area Phone #: ###-#### >> Inspection requested via web by Patrick D Gill rough-in ok cover lobby walls and soffits
|
ELE13-00553
| Electrical Rough-In | 4/3/2013 | 4/4/2013 | 4/4/2013 12:17:14 PM | A | PASS |
|
|
Wall inspection in warehouse. Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok cover warehouse walls
|
ELE13-00792
| Conference | 4/3/2013 | 4/4/2013 | 4/4/2013 11:56:10 AM | A | DONE |
|
|
steven Phone #: ###-#### Discussed with homeowner requirements for new dwelling addition
|
ELE12-02856
| Final | 4/3/2013 | 4/4/2013 | 4/4/2013 11:02:40 AM | A | FAIL |
|
|
pedro Phone #: ###-#### NEC 406.8(B)(1) Requires exterior receptacles to be listed WR weather resistance type, with weather-proof cover suitable for use in wet locations. Overhead service conductors don't meet minimun clearance reqirements do to new structure placement. NEC 110.26 required working clearance in front of service meter
|
ELE13-00746
| Electrical Rough-In | 4/3/2013 | 4/4/2013 | 4/4/2013 10:27:04 AM | A | PASS |
|
|
Need ufer ground inspection. Field Super Treon McCormack ###-#### Phone #: ###-#### >> Inspection requested via web by Kevin Perez rough-in ok cover concrete encased electrode
|
ELE13-00799
| Electrical Rough-In | 4/4/2013 | 4/4/2013 | 4/4/2013 9:49:14 AM | A | PASS |
|
|
soffit inspection Phone #: ###-#### >> Inspection requested via web by Therrin Robertson rough-in ok cover exterior soffits only
|
ELE13-00086
| Electrical Rough-In | 4/3/2013 | 4/4/2013 | 4/4/2013 9:35:12 AM | A | PASS |
|
|
Dave. Underground. Phone #: ###-#### >> Inspection requested via web by Sean DeLacy rough-in ok cover exterior underground,East half parking lot lighting . conduits between pole bases
|
ELE13-00795
| Electrical Rough-In | 4/3/2013 | 4/4/2013 | 4/4/2013 8:43:09 AM | A | PASS |
|
|
Cover inspection for walls and ceilings Phone #: ###-#### >> Inspection requested via web by Thomas Jenkins rough-in ok cover ceiling grid
|
ELE13-00261
| Final | 4/4/2013 | 4/4/2013 | 4/4/2013 8:24:51 AM | A | PASS |
|
|
Call Dene for access code Thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser final ok
|
ELE13-00289
| Final | 4/3/2013 | 4/4/2013 | 4/4/2013 8:11:56 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Joe Thomas final ok
|
ELE13-00277
| Final | 4/3/2013 | 4/4/2013 | 4/4/2013 8:10:37 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Joe Thomas final ok
|
ELE13-00783
| Electrical Rough-In | 4/3/2013 | 4/4/2013 | 4/3/2013 1:56:02 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Eric Brown rough-in ok cover remodel
|