ESC13-00144
| General Inspection | 4/4/2014 | 4/4/2014 | 4/4/2014 11:11:38 AM | | PASS |
|
|
No new activity
|
ESC13-00755
| Tracking Control | 4/4/2014 | 4/4/2014 | 4/4/2014 11:11:14 AM | P | PART |
|
|
Follow up on the Terraces project. Roads are being swept 1-2 times per day according to foreman JC Murray. Trackout at roundabout is not bad, but need to sweep entrance at Council Springs today.
JC stated that today more pit run is being brought in to increase length of constructions entrances at both ends, if not through the entire site.
Need to continue sweeping. Will check silt fences next week.
|
ESC14-00104
| Tracking Control | 4/4/2014 | 4/4/2014 | 4/4/2014 10:48:27 AM | P | FAIL |
|
|
Tracking from foundation pouring trucks needs to be cleaned up. Big mud clods should be shoveled Brighton RP issued verbal warning for projects in Mill District Square.
|
ESC13-01140
| Random Inspection | 4/4/2014 | 4/4/2014 | 4/4/2014 10:45:59 AM | P | FAIL |
|
|
Concrete being poured for foundation. Trucks are using designated washout but tracking mud clods down alley and street.
Verbal warning issued to Brighton Homes RP Josh Edwards via phone to have crew clean up once concrete is poured.
|
ESC13-00951
| General Inspection | 4/4/2014 | 4/4/2014 | 4/4/2014 10:36:16 AM | | PASS |
|
|
Frame is up. Workers staying off mud. No corrections at this time.
|
ESC13-00522
| General Inspection | 4/4/2014 | 4/4/2014 | 4/4/2014 10:32:12 AM | | PASS |
|
|
Retaining wall is complete and has been approved by PW. The slope above is still in process of vegetation. Will keep open until full stabilization is accomplished.
|
ESC13-00501
| General Inspection | 4/4/2014 | 4/4/2014 | 4/4/2014 10:04:09 AM | | PASS |
|
|
|
ESC13-00854
| General Inspection | 4/4/2014 | 4/4/2014 | 4/4/2014 9:46:37 AM | | PASS |
|
|
No activity or violations observed at time of inspection. No activity on BLD permit, unclear if project is complete, will continue to monitor. Low risk site.
|
ESC13-00649
| General Inspection | 4/4/2014 | 4/4/2014 | 4/4/2014 9:44:38 AM | | PASS |
|
|
WIP. See activity notes for ESC13-00650.
|
ESC13-00650
| General Inspection | 4/4/2014 | 4/4/2014 | 4/4/2014 9:44:03 AM | | PASS |
|
|
Finaled.
|
ESC13-00650
| DOC - Permit Finaled | 4/4/2014 | 4/4/2014 | 4/4/2014 9:43:44 AM | P | PASS |
|
|
Expansion has been complete, some vertical construction is remaining. The grading and grubbing phase under this permit is complete. ESC13-00650 covers south warehouse, and ESC13-00277 for north side office expansion are still open. No violations.
|
ESC13-01263
| Random Inspection | 4/4/2014 | 4/4/2014 | 4/4/2014 9:14:46 AM | P | PASS |
|
|
BMPs installed. Construction entrance is good condition. Some minor trackout; DIs protected
|
ESC13-00814
| Aging Inspection | 4/4/2014 | 4/4/2014 | 4/4/2014 9:10:10 AM | | PASS |
|
|
Finaled.
|
ESC13-00814
| DOC - Permit Finaled | 4/4/2014 | 4/4/2014 | 4/4/2014 9:09:57 AM | P | PASS |
|
|
House complete. ESC conditions satisfied.
|